B Parameter Table

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

215

Pa

ra

me

te

r T

abl

e

B

Note: Fault trace (i.e., the fault history) is not maintained when CPF00, CPF01, CPF06, CPF24, oFA00, oFb00, oFC00, Uv1, Uv2, or Uv3

occur.

U6: Control Monitors

U4-43

(856H)

<35>

Minimum Deceleration
Distance

Displays the Minimum Deceleration Distance calculated by E1-04.

No signal output
available

1 mm

U4-44

(857H)

<35>

Minimum Stop Distance

Displays the Minimum Stop Distance calculated by d1-26.

No signal output
available

1 mm

<31> Setting units are determined by the digital operator display unit selection (o1-03). When o1-03 = 0, the value is set in Hertz. When o1-03 = 4 or

5, the value is displayed in m/s. When o1-03 = 6, the value is displayed in ft/min.

<35> o1-12 (Length Units) determines the units. When o1-12 is set to 0, the unit is millimeters. When o1-12 is set to 1, the unit is inch.

<40> When checking the values of U1-03, U2-05 and U4-13 with the digital operator they are displayed in units of amperes, but when they are

checked using MEMOBUS communications, the monitor value in MEMOBUS communications is: displayed numeric value / 8192

× drive’s

rated current (A), from the condition “8192 (maximum value) = drive’s rated current (A)”.

<41> The MEMOBUS communications data is in 10 h units. If data in 1 h units are also required, refer to register number 0099H.

<42> The MEMOBUS communications data is in 10 h units. If data in 1 h units are also required, refer to register number 009BH.

No.

(Addr.)

Name

Description

Analog Output

Level

Unit

U6-01

(51H)

Motor Secondary Current
(Iq)

Displays the value of the motor secondary current (Iq). Motor rated secondary
current is 100%.

10 V: Motor
secondary rated
current
(-10 to +10 V)

0.1%

U6-02

(52H)

Motor Excitation Current
(Id)

Displays the value calculated for the motor excitation current (Id). Motor rated
secondary current is 100%.

10 V: Motor
secondary rated
current
(-10 to +10 V)

0.1%

U6-03

(54H)

Speed Control Loop
Input

Displays the input and output values of the speed control loop.

10 V: Max
frequency
(-10 to +10 V)

0.01%

U6-04

(55H)

Speed Control Loop
Output

10 V: Motor
secondary rated
current
(-10 to +10 V)

U6-05

(59H)

Output Voltage
Reference (Vq)

Output voltage reference (Vq) for the q-axis.

10 V: 200
Vrms

<9>

(-10 to +10 V)

0.1 Vac

U6-06
(5AH)

Output Voltage
Reference (Vd)

Output voltage reference (Vd) for the d-axis.

10 V: 200
Vrms

<9>

(-10 to +10 V)

0.1 Vac

U6-07

(5FH)

q-Axis Current
Controller Output

Displays the output value for current control relative to motor secondary
current (q-axis).

10 V: 200
Vrms

<9>

(-10 to +10 V)

0.1%

U6-08

(60H)

d-Axis Current
Controller Output

Displays the output value for current control relative to motor secondary
current (d-axis).

10 V: 200
Vrms

<9>

(-10 to +10 V)

0.1%

U6-13

(7CAH)

Flux Position Detection
(sensor)

Monitors the value of the flux position detection (sensor).

10 V: 180 deg
-10 V: -180 deg

0.1 deg

U6-18

(7CDH)

Speed Detection PG1
Counter

Monitors the number of pulses for speed detection (PG1).

10 V: 65536

1 pulse

U6-22

(62H)

Position Lock Deviation
Counter

Displays how far the rotor has moved from its last position in PG pulses
(multiplied by 4).

10 V: No. of
pulses per
revolution
(-10 to +10 V)

1 pulse

No.

(Addr.)

Name

Description

Analog Output

Level

Unit

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV