Auto-tuning interruption and fault codes, Auto-tuning operation example, Yea_ c o m – Yaskawa L1000E AC Drive CIMR-LE†A User Manual

Page 70: 4 start-up programming, Figure 45 auto-tuning aborted display, Auto-tuning aborted during auto-tuning

background image

4 Start-Up Programming

70

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

Note: 1. The motor rotates during execution of Auto-Tuning of PG-E3 encoder characteristics. Before starting, refer to the drive technical

manual.

2. Auto-Tuning of PG-E3 encoder characteristics adjusts the unique characteristics of the ERN1387 encoder connected to the drive by

using a PG-E3 option card. This type of tuning should be performed when setting up the drive or after replacing the encoder or drive.
The signal lines between the PG-E3 option card and the ERN1387 encoder must be connected between the R+ and R- terminals while
this type of tuning is performed.

3. The setting values of parameters F1-66 to F1-81 are reset to factory default values when A1-03 is set to 2220. The setting values of

parameters F1-66 to F1-81 are modified at completion of Auto-Tuning of PG-E3 encoder characteristics.

Auto-Tuning Interruption and Fault Codes

If tuning results are abnormal or the STOP key is pressed before completion, Auto-Tuning will be interrupted and a fault
code will appear on the digital operator.

Figure 41

Figure 45 Auto-Tuning Aborted Display

Auto-Tuning Operation Example

The following example demonstrates Rotational Auto-Tuning when using OLV (A1-02 = 2).

Selecting the Type of Auto-Tuning

Enter Data from the Motor Nameplate

After selecting the type of Auto-Tuning, enter the data required from the motor nameplate.

Step

Display/Result

1.

Turn on the power to the drive. The initial display appears.

2.

Press

or

until the Auto-Tuning display appears.

3.

Press

to begin setting parameters.

4.

Press

to select the value for T1-01.

5.

Save the setting by pressing

.

6.

The display automatically returns to the display shown in Step 3.

DIGITAL OPERATOR JVOP-180

DIGITAL OPERATOR JVOP-180

REV

DRV

FOUT

DRV

ALM

ALM

Auto-Tuning Aborted

During Auto-Tuning

- A.TUNE -

X.XX Hz/ X.XXA

DRV

Tune Proceeding

Rdy

FWD

- MODE -

Er-03

STOP key

DRV

FWD

RESET

YEA_

c o m -

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref (OPR)

Rdy

FWD

FWD/REV

RSEQ
LREF

HELP

- MODE -

PRG

Auto-Tuning

DATA

AUTO

FWD

- A.TUNE -

T1-

01

= 0

∗0∗

Standard Tuning

PRG

Tuning Mode

ESC

FWD

DATA

- A.TUNE -

T1-01=

0

∗0∗

Standard Tuning

PRG

Tuning Mode

FWD

“0”

Entry Accepted

- A.TUNE -

T1-

01

= 0

∗0∗

Standard Tuning

PRG

Tuning Mode

ESC

FWD

DATA