4 Start-Up Programming

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

87

St

ar

t-

Up

Pr

og

ra

m

m

in

g

4

After setting load conditions 1 and 2, perform a trial run. If required, parameter S3-12 can be set up to add a bias to the
load sensor input when riding in a Down direction (default: 0.0%, same torque compensation characteristics in up and
down direction).

Figure 53

illustrates the effect of torque compensation on the settings of S3-12 and S3-27 through S3-

30.

Figure 48

Figure 53 Torque Compensation at Start for the Elevator in Up and Down Direction

S3-30

S3-27

S3-28

(Torque Compensation
Value with Load Condition 2)

Torque Compensation
at Start for the Elevator
in the Down Direction

S3-29

(Analog Input
from Load Sensor
with Load
Condition 1)

(Torque Compensation Value
with Load Condition 1)

During Load Condition 2

Torque Compensation
at Start for the Elevator
in the Up Direction

S3-12 (Starting Torque
Compensation Bias during Lowering)

(Analog input
from Load Sensor
with Load Condition 2)

Analog Input Voltage (V)

During Load Condition 1

0