beautypg.com

B parameter table – Yaskawa L1000E AC Drive CIMR-LE†A User Manual

Page 174

background image

B Parameter Table

174

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

E3: V/f Pattern for Motor 2

These parameters are hidden when a PM motor control mode has been selected for motor 1 (A1-02 = 7).

E2-06

(313H)

Motor Leakage Inductance

Sets the voltage drop due to motor leakage inductance as a percentage of motor
rated voltage. Automatically set during Auto-Tuning.

Default:

<4>

Min: 0.0%
Max: 40.0%

E2-07

(314H)

Motor Iron-Core Saturation
Coefficient 1

Sets the motor iron saturation coefficient at 50% of magnetic flux. Automatically
set during Auto-Tuning.

Default: 0.50
Min: 0.00
Max: 0.50

E2-08

(315H)

Motor Iron-Core Saturation
Coefficient 2

Sets the motor iron saturation coefficient at 75% of magnetic flux. Automatically
set during Auto-Tuning.

Default: 0.75
Min: E2-07
Max: 0.75

E2-09

(316H)

Motor Mechanical Loss

Sets the motor mechanical loss as a percentage of motor rated power (kW).

Default: 0.0%
Min: 0.0%
Max: 10.0%

E2-10

(317H)

Motor Iron Loss for Torque
Compensation

Sets the motor iron loss.

Default:

<4>

Min: 0 W
Max: 65535 W

E2-11

(318H)

Motor Rated Power

Sets the motor rated power in kilowatts (1 HP = 0.746 kW). Automatically set
during Auto-Tuning.

Default:

<4>

Min: 0.00 kW
Max: 650.00 kW

<4> Default setting value varies by the drive model (o2-04).

<10> The display resolution depends on the rated output power of the drive. Models 2A0018 to 2A0041 and 4A0009 to 4A0023 display values in

0.01 A units, while models 2A0059 to 2A0432 and 4A0030 to 4A0260 display values in 0.1 A units.

No.(Addr.)

Name

Description

Setting

E3-04

(31AH)

<4> Default setting value is dependent on the drive model (o2-04).

<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.

Motor 2 Maximum Output
Frequency

These parameters are only applicable when E1-03 is set to F.
To set linear V/f characteristics, set the same values for E3-07 and E3-09. In this
case, the setting for E3-08 will be disregarded. Ensure that the three frequencies
are set according to these rules or an oPE10 fault will occur:
E3-09

≤ E3-07 < E3-06 ≤ E3-04

Default: 60.0 Hz
Min: 10.0 Hz
Max: 200.0 Hz

E3-05

(31BH)

Motor 2 Maximum Voltage

Default: 230.0 V
Min: 0.0 V
Max: 255.0 V

<9>

E3-06

(31CH)

Motor 2 Base Frequency

Default: 60.0 Hz
Min: 0.0 Hz
Max: 200.0 Hz

E3-07

(31DH)

Motor 2 Mid Output
Frequency

Default: 3.0 Hz
Min: 0.0 Hz
Max: 200.0 Hz

E3-08

(31EH)

Motor 2 Mid Output
Frequency Voltage

Default:

<4>

Min: 0.0 V
Max: 255.0 V

<9>

E3-09

(31FH)

Motor 2 Minimum Output
Frequency

Default: 1.5 Hz
Min: 0.0 Hz
Max: 200.0 Hz

E3-10

(320H)

Motor 2 Minimum Output
Frequency Voltage

Default:

<4>

Min: 0.0 V
Max: 255.0 V

<9>

No.(Addr.)

Name

Description

Setting

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

CLV

CLV/PM

V/f

OLV

common

_

E3-05

E3-08

E3-10

E3-09

E3-07

E3-04

Output Voltage (V)

Frequency (Hz)