B parameter table – Yaskawa L1000E AC Drive CIMR-LEA User Manual
Page 197
B Parameter Table
YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide
197
Pa
ra
me
te
r T
abl
e
B
o1-02
(501H)
User Monitor Selection after
Power Up
o1-02 selects the information that is displayed when the power is turned on.
1: Speed reference (U1-01)
2: Direction
3: Output speed (U1-02)
4: Output current (U1-03)
5: User-selected monitor (set by o1-01)
Default: 1
Min: 1
Max: 5
o1-03
(502H)
Digital Operator Display Unit
Selection
Sets the units the drive should use to display the frequency reference and motor
speed monitors.
0: 0.01 Hz
1: 0.01% (100% = E1-04)
2: r/min (calculated using the number of motor poles setting in E2-04, E4-04, or
E5-04)
3: User-selected units (set by o1-10 and o1-11)
4: Elevator units 1 (speed in m/s, accel/decel rate and jerk in s)
5: Elevator units 2 (speed in m/s, accel/decel rate in m/s
2
, jerk in m/s
3
)
6: Elevator units 3 (speed in ft/min, accel/decel rate in ft/s
2
, jerk in ft/s
3
)
Default: 1
Min: 0
Max: 6
o1-04
(503H)
V/f Pattern Setting Units
0: Hz
1: r/min
Default:
Min: 0
Max: 1
o1-05
(504H)
LCD Contrast Control
Adjusts the brightness and contrast of the LCD screen on the digital operator.
Default: 3
Min: 0
Max: 5
o1-06
(517H)
User Monitor Selection Mode 0: 3 Monitor Sequential (Displays the next 2 sequential monitors)
1: 3 Monitor Selectable (o1-07 and o1-08 selected monitor is displayed)
Default: 0
Min: 0
Max: 1
o1-07
(517H)
Second Line Monitor
Selection
Selects the monitor displayed on the second line.
Default: 102
Min: 101
Max: 699
o1-08
(517H)
Third Line Monitor Selection
Selects the monitor displayed on the third line.
Default: 103
Min: 101
Max: 699
o1-10
(520H)
User-Set Display Units
Maximum Value
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output frequency.
o1-11 sets the position of the decimal position.
Default:
Min: 1
Max: 60000
o1-11
(521H)
User-Set Display Units
Decimal Display
Default:
Min: 0
Max: 3
o1-12
(739H)
Length Units
0: Millimeter unit
1: Inch unit
Default: 0
Min: 0
Max: 1
o1-20
(575H)
Traction Sheave Diameter
Sets the traction sheave diameter for display unit calculations.
Default: 400 mm
Min: 100 mm
Max: 2000 mm
o1-21
(576H)
Roping Ratio
Sets the roping ratio.
1: 1:1
2: 1:2
3: 1:3
4: 1:4
Default: 2
Min: 1
Max: 4
o1-22
(577H)
Mechanical Gear Ratio
Sets the ratio of the gear installed for display unit calculations.
Default:
Min: 0.10
Max: 100.00
No.
(Addr.)
Name
Description
Setting
All Modes
common
_
All Modes
common
_
common
_
CLV
CLV/PM
V/f
OLV
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
All Modes
common
_
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV