B Parameter Table

176

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

F: Option Settings

F parameters are used to program the drive for Encoder and PG feedback from the motor and to function with option
cards.

F1: PG Speed Control Card

E5-11

(333H)

Encoder Offset

Sets the offset between the rotor magnetic axis and the encoder zero position. Set
during Encoder Offset Tuning.

Default: 0.0 deg
Min: -180 deg
Max: 180 deg

E5-24

(353H)

Motor Induction Voltage Constant 2

Sets the induced phase-to-phase rms voltage in units of 0.1 mV/(r/min)
[mechanical angle].
When setting this parameter, E5-09 should be set to 0.0.

Default:
0.0 mV/(r/min)

Min:
0.0 mV/(r/min)

Max:
6500.0 mV/(r/min)

<1> Parameter setting value is not reset to the default value when the drive is initialized.

<2> Default setting value is determined by the drive model (o2-04).

<3> The display resolution depends on the rated output power of the drive. Models 2A0018 to 2A0041 and 4A0009 to 4A0023 display values in 0.01

A units, while models 2A0059 to 2A0432 and 4A0030 to 4A0260 display values in 0.1 A units.

<4> Maximum setting is 48 when PG-E3 option is connected.

No.(Addr.)

Name

Description

Setting

F1-01

(380H)

Encoder 1 Resolution

Sets the encoder resolution (number of pulses per revolution)

Default:

<1>

Min: 1 ppr
Max: 60000 ppr

<2>

F1-02

(381H)

Operation Selection at PG
Open Circuit (PGo)

0: Ramp to stop. Decelerate to stop using the deceleration ramp in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration ramp in C1-09.
3: Alarm only.

Default: 1
Min: 0
Max: 3

F1-03

(382H)

Operation Selection at
Overspeed (oS)

0: Ramp to stop. Decelerate to stop using the deceleration ramp in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration ramp in C1-09.
3: Alarm only.

Default: 1
Min: 0
Max: 3

F1-04

(383H)

Operation Selection at
Deviation

0: Ramp to stop. Decelerate to stop using the deceleration ramp in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration ramp in C1-09.
3: Alarm only.

Default: 3
Min: 0
Max: 3

F1-05

(384H)

Encoder 1 Rotation Direction
Selection

0: A phase leads B in up direction
1: B phase leads A in up direction

Default:

<1>

Min: 0
Max: 1

F1-06

(385H)

PG 1 Pulse Monitor Output
Division Ratio

Sets the division ratio for the pulse monitor used of the PG option card installed
to connector CN5-C. By setting “xyz”, the division ratio becomes = [(1 + x) /
yz]. If only using the A pulse for one track input, then the input ratio will be 1:1,
regardless of what F1-06 is set to.

Default: 1
Min: 1
Max: 132

F1-08

(387H)

Overspeed Detection Level

Sets the overspeed detection level as a percentage of the maximum output
frequency.

Default: 115%
Min: 0%
Max: 120%

F1-09

(388H)

Overspeed Detection Delay
Time

Sets the time in seconds for an overspeed situation to trigger a fault (oS).

Default: 0.0 s
Min: 0.0 s
Max: 2.0 s

No.(Addr.)

Name

Description

Setting

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV