B Parameter Table

204

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

S5: Short Floor Operation

S4-07

(6CDH)

UPS Power

Sets the capacity of the UPS.

Default: 0.0 kVA
Min: 0.0 kVA
Max: 100.0 kVA

S4-08

(6CEH)

UPS Operation Speed Limit
Selection

Determines how a speed limit should be applied to the Rescue Operation speed
(d1-25) when operating from a UPS.
0: Disabled
1: Enabled until Light Load Direction Search is complete
2: Enabled until stop

Default: 2
Min: 0
Max: 2

S4-12

(6D2H)

DC Bus Voltage during
Rescue Operation

Sets the DC bus voltage during Rescue Operation.

Default: 0 V
Min: 0 V
Max: 800 V

S4-13

(6D3H)

Rescue Operation Power
Supply Deterioration
Detection Level

Determines at which level of backup power supply deterioration a PF5 fault is
triggered.

Default: 80%
Min: 10%
Max: 100%

S4-15

(6DAH)

Speed Reference Selection
for Rescue Operation

Selects the speed reference used for Rescue Operation.

Default: 0
Min: 0
Max: 1

<5> Default setting is determined by the control mode (A1-02).

No.

(Addr.)

Name

Description

Setting

S5-01

(6ABH)

Short Floor Operation
Selection

0: Disabled
1: Enabled (Short Floor)
2: Enabled (Advance Short Floor)

Default: 0
Min: 0
Max: 2

S5-02

(6ACH)

Nominal Speed for Short
Floor Calculation

When d1-18 (Speed Priority Selection) is set to 0 or 3, S5-02 determines the
rated speed used during Short Floor.

Default: 0.0%
Min: 0.0%
Max: 100.0%

S5-03

(6ADH)

Short Floor Minimum
Constant Speed Time

Sets the minimum operation time when the Advanced Short Floor function is
enabled (S5-01 = 2).

Default: 0.0 s
Min: 0.0 s
Max: 2.0 s

S5-04

(6AEH)

Distance Calculation
Acceleration Time Gain

Set for acceleration jerk compensation in Distance Calculation.

Default: 150.0%
Min: 50.0%
Max: 200.0%

S5-05

(6AFH)

Distance Calculation
Deceleration Time Gain

Set for deceleration jerk compensation in Distance Calculation.

Default: 150.0%
Min: 50.0%
Max: 200.0%

S5-10

(6B0H)

Stopping Method Selection

0: Disabled
1: Direct Landing
2: Leveling Distance Control

Default: 0
Min: 0
Max: 2

S5-11

(6B1H)

Deceleration Distance

Sets the deceleration distance when Stop Distance Control is enabled.

Default: 0 mm
Min: 0 mm
Max: 32767 mm

<36>

S5-12

(6B2H)

Stop Distance

Sets the stopping distance when Stop Distance Control is enabled.

Default: 0 mm
Min: 0 mm
Max: 10000 mm

<37>

No.

(Addr.)

Name

Description

Setting

All Modes

common

_

All Modes

common

_

common

_

All Modes

common

_

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_