beautypg.com

Powering up the drive and operation status display, 4 start-up programming – Yaskawa L1000E AC Drive CIMR-LE†A User Manual

Page 55

background image

4 Start-Up Programming

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

55

St

ar

t-

Up

Pr

og

ra

m

m

in

g

4

Powering Up the Drive and Operation Status Display

Powering Up the Drive

Perform the following power-off checks before applying main power to the drive.

WARNING! Electrical Shock Hazard. Do not contact live electrical parts. Failure to comply could result in death or serious injury. Never

touch the output terminals directly with your hands or allow the output lines to come into contact with the drive case.

WARNING! Sudden Movement Hazard. Operating a drive with untested emergency circuits could result in death or serious injury.

Always check the operation of drive fast stop circuits and any additional emergency circuits after they are wired. Fast stop circuits are

required to provide safe and quick shutdown of the drive.

WARNING! Sudden Movement Hazard. Ensure start/stop and safety circuits are wired properly and in the correct state before

energizing the drive. Failure to comply could result in death or serious injury from moving equipment.

Status Display

When the power supply to the drive is turned on, the digital operator lights will appear as follows:

9

Function Key 2

(F2)

FWD/REV

Pressing

switches

between Up and Down when the Up/Down command is set from

the digital operator.

DATA

Pressing

scrolls to the next display.

Pressing

scrolls

the

cursor to the right.

RESET

Pressing

resets the existing drive fault or error.

<1> Displayed when in Drive Mode.

<2> Displayed when in Drive Mode and Monitor Mode.

Power-off Checks

Description

Power supply voltage

Ensure the power supply voltage is correct on the supply side of the disconnect, before applying power to the
drive.
200 V class: 3-phase 200 to 240 Vac 50/60 Hz
400 V class: 3-phase 380 to 480 Vac 50/60 Hz
Properly wire the power supply input terminals (R/L1, S/L2, T/L3). Check for correct wiring, terminals are
tightened, and there are no loose wire strands.
Check for proper grounding of drive and motor.

Drive output terminals and
motor terminals

Properly wire drive output terminals U/T1, V/T2, and W/T3 with motor terminals U/T1, V/T2, and W/T3.
Check for correct wiring, terminals are tightened, and there are no loose wire strands.

Control circuit terminals

Check control circuit terminal connections. Check that control circuit terminals are correctly wired, terminals
are tightened, and there are no loose wire strands.

Drive control terminal status

Open all control circuits to the drive I/O terminal block.

No.

Name

Description

Normal

Operation

The data display area in the upper half of the display, displays the speed reference. DRV
is displayed.

Fault

External fault (example)

Data displayed varies by the type of fault.

Refer to Fault Displays, Causes, and

Possible Solutions on page 130

for more information and possible solutions. ALM

LED is lit and DRV displayed.

No.

Name

Display

Content

F1

F1

F1

F1

DIGITAL OPERATOR JVOP-180

ALM

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref (OPR)

Rdy

FWD

RSEQ
LREF

YEA_

c o m -

DIGITAL OPERATOR JVOP-180

ALM

- MODE -

EF3

Ext Fault S3

DRV

FWD

RESET

YEA_

c o m -