H4: Analog Outputs

2

Auxiliary Speed Reference 1
(used as a second speed reference)

E1-04 (maximum output frequency)

3

Auxiliary Speed Reference 2
(used as third speed reference)

E1-04 (maximum output frequency)

E

Motor Temperature (PTC thermistor input)

oH3 Alarm detection level: 1.18 V
oH4 Fault detection level: 2.293 V

14

Torque Compensation (load cell input)

10 V = Motor rated torque

1F

Not used (Through Mode)

Sets this value when the terminal is not used or when using the terminal in the pass-through
mode

.

No.(Addr.)

Name

Description

Setting

H4-01

(41DH)

Terminal FM Monitor
Selection

Selects the data to be output through multi-function analog output terminal FM.
Set the desired monitor parameter to the digits available in U -

. For

example, enter “103” for U1-03.

Default: 102
Min: 000
Max: 999

H4-02

(41EH)

Terminal FM Gain

Sets the signal level at terminal FM that is equal to 100% of the selected monitor
value.

Default: 100.0%
Min: -999.9%
Max: 999.9%

H4-03

(41FH)

Terminal FM Bias

Sets the bias value added to the terminal FM output signal.

Default: 0.0%
Min: -999.9%
Max: 999.9%

H4-04

(420H)

Terminal AM Monitor
Selection

Selects the data to be output through multi-function analog output terminal AM.
Set the desired monitor parameter to the digits available in U -

. For

example, enter “103” for U1-03.

Default: 103
Min: 000
Max: 999

H4-05

(421H)

Terminal AM Gain

Sets the signal level at terminal AM that is equal to 100% of the selected monitor
value.

Default: 50.0%
Min: -999.9%
Max: 999.9%

H4-06

(422H)

Terminal AM Bias

Sets the bias value added to the terminal AM output signal.

Default: 0.0%
Min: -999.9%
Max: 999.9%

H4-07

(423H)

Terminal FM Signal Level
Selection

0: 0 to 10 V
1: –10 to 10 V

Default: 0
Min: 0
Max: 1

H4-08

(424H)

Terminal AM Signal Level
Selection

0: 0 to 10 V
1: –10 to 10 V

Default: 0
Min: 0
Max: 1

H3 Multi-Function Analog Input Settings (H3-02 and H3-10)

Setting

Function

Description (For when output is 100%)

All Modes

common

_

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_