CMG-EAM (Platinum Firmware)

The final section of the digitiser control web page is entitled

“Miscellaneous features”. This section displays a warning in red if a
discrepancy is detected between the EAM's time and the digitiser's

own clock. If the two clocks have reasonable synchronisation, this
message is suppressed. A typical warning looks like this:

Digitiser clock is displaced by more than 5 minutes from the system clock.
(Plus 7 minutes.)

This section of the page is shown here without the warning:

The first check-box enables the transmission of Unified Status Packets.
Unified Status Packets are a machine-readable representation of the

data carried in the normal, human-readable status streams and allow
programs such as Scream! to access complete and consistent state-of-

health information regardless of any status stream customisations.

The second check-box allows the one-time re-synchronisation of the
digitiser to the EAM's system clock. The third toggles display of the

underlying dialogue with the digitiser, as described at the beginning of
this section.

Note that, as with all web interfaces, options selected on this screen

will not take effect until the page is submitted.

Extra buttons at the bottom of this page allow the refreshing of the web
page display with up-to-date information and offer the opportunity to

reboot the digitiser.

88

Issue C

Note: Some digitiser configuration changes require the digitiser
to be rebooted before they will take effect. Please consult the

digitiser manual for more information.