beautypg.com

1 select: (main) menu, 2 select: configuration – Comtech EF Data CDM-760 User Manual

Page 92

background image

Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–6

6.2.1 SELECT: (Main) Menu

When the modem is running with Carrier-in-Carrier installed and turned ON,

you will see the blinking “CnC” symbol, shown here, at the far right of the top

line of the SELECT: (main), SELECT: Monitor, and SELECT: TEST menu screens. If you

do not see this symbol, it means that Carrier-in-Carrier is either not installed, or it

is installed but turned OFF.

SELECT: Configuration Monitor Test

Store/Ld Utility ODU FAST ()

Use the   arrow keys to select a menu branch. Press ENTER.

The SELECT: (main) menu provides the access entry point for all other modem configuration,

monitor, and control operations. These menu branches and their submenus are described in the

sections that follow.

6.2.2 SELECT: Configuration

CONFIG: NetSpec Tx Rx Intf CnC Comp

Remote IP Mask Ref MEO ()

Use the   arrow keys to select a submenu. Press ENTER.

CONFIG

Submenu

Description

NetSpec

(Network Specification) Use to configure the top level network specification mode (DVB-S2 Open

Standard or DVB-S2-EB1 High Efficiency waveform and ModCod selections), and to select between

as well as select between Normal and Medium Earth Orbit (MEO) operating modes.

Tx

(Transmit) Use to define the Tx configuration of the unit on a per-parameter basis.

Rx

(Receive) Use to define the Rx configuration of the unit on a per-parameter basis.

Intf

(Interface) Use to configure the operating status of the installed optional Plug-in Interface Cards

(PIICs), optional J7 | OPTICAL port, or the optional High-Speed Packet Processor, plus the

operating speed of Gigabit Ethernet Interface Ports GBEI1 (J5 | DATA) and GBEI2 (J6 | DATA).

CnC

(DoubleTalk

Carrier-in-Carrier) Use to select DoubleTalk

Carrier-in-Carrier (CnC) options.

Comp

Use to configure optional K4 GZip lossless compression and decompression operation.

Remote

(Remote Control) Use to define whether the unit can be controlled remotely via IP, serial, or both,

and to configure the serial remote parameters.

NOTE: Local Mode is always enabled.

IP

Use to configure various IP parameters, including IP address/range and gateway addresses, and to

view MAC addresses.

Mask

Use to treat certain operational criteria as faults or alarms, or to mask (ignore) the conditions.

Ref

Use to select and configure the Frequency Reference as External or Internal, and to fine-adjust the

Internal Hi-Stability 10 MHz Reference.

MEO

Use to select and configure the MEO (Medium Earth Orbit) and AHO (Antenna Handover) features