Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–22

1)

If you are in MultiStream Mode, the buffer depth is calculated using only the

Ethernet data rate – not the aggregate data rate.

2)

The WAN Buffer is a FIFO (First In First Out) buffer, not a circular buffer. This

means that, as long as the Ethernet ingress to the modem does not exceed the

Ethernet Data Rate of the modem, the buffer will always remain relatively

empty and there will be NO ADDED LATENCY. The buffer will begin to fill and

you will experience added latency only when the Ethernet traffic ingress to the

modem exceeds the egress of the Ethernet data rate.

3)

By enabling Flow Control, the modem begins to send Pause Frames to any

device connected to the Ethernet Data Interfaces at approximately 87%

capacity. Pause Frames cease to be sent to the Ethernet Interfaces when the

WAN Buffer Full Status drops below 75% capacity. See (CONFIG: INTF)(GBEIX)

FlowControl in Sect. 6.2.2.4.2 for more information about Flow Control.

6.2.2.3 (CONFIG:) Rx

Rx: Mod Data Freq EsNo

Data 155520.000kbps 060140.976ksps

()

On the top line Use the   arrow keys to select a parameter. Press ENTER.

The read-only bottom line shows the operating data rate (in kbps) and symbol rate (in ksps).

The Data rate displays “00000.000kbps” when the demodulator is unlocked.

6.2.2.3.1 (CONFIG: Rx) Mod

This screen displays “Demodulator Is Not Locked” if the demodulator is unlocked.

ModCod=8PSK 8/9 Frame:Normal

Pilots:On

()

This read-only screen identifies the active modulation type, coding, Framing Mode, and Pilot

setting.