Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–36

On the top line, the letter ‘X’ in PIICX represents the slot number (PIIC1 or PIIC2) containing the

optional interface. Use the   arrow keys to select a parameter. Press ENTER.

(CONFIG: INTF) (PIICX=OC3/STM1) Type

Use the  arrow keys to select NONE or OC3/STM1. Press ENTER.

You can access these menus only when the standard PIIC slots card is installed and

the modem senses the presence of an optional PIIC module.

In Single Stream Mode, an OC3/STM1 PIIC interface with a setting of OC3/STM1 fixes the

modem data rate to the correct speed. The symbol rate is linked to this fixed data rate, so that it

adjusts automatically when changes occur to the modulation, coding, pilots, or Tx frame block

size.

The activated symbol rate or CnC FAST Option must be compatible with the symbol

or data rate for the selected interface.

(CONFIG: INTF) (PIICX=OC3/STM1) ClkSource

ClkSource: TXClock: TX CLK

RXClock: RX SAT

()

Use the   arrow keys to select a parameter. Press ENTER.

(CONFIG: INTF) (PIICX=OC3/STM1) ClkSource TXClock

Lock the Tx symbol rate of the modulator to the applicable clock source. Use the 

arrow keys to select RX SAT or TX CLK. Press ENTER.

Comtech EF Data strongly suggests that you select TX CLK, unless a high-

stability EXT CLK is present and timing of the network requires all devices to

be locked to the EXT CLK.

(CONFIG: INTF) (PIICX=OC3/STM1) ClkSource RXClock

Set the clock source by which Rx data is clocked out of the OC3/STM1 interface to the

external baseband equipment. Use the  arrow keys to select RX SAT or TX CLK.

Press ENTER.

Comtech EF Data strongly suggests that you select RX SAT, unless a high-

stability EXT CLK is present and timing of the network requires all devices

to be locked to the EXT CLK.