10 odu parameters – Comtech EF Data CDM-760 User Manual
Page 267
Serial-based Remote Product Management
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
8–33
8.5.10 ODU Parameters
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
LNB 10MHz
Reference
Enable
LNR =
1 byte, value
of 0 or 1
Command or Query.
Enables or disables LNB 10MHz Reference Enable in the form x, where:
0 = Disable LNB Reference
1 = Enable LNB Reference
LNR=
LNR?
LNR*
LNR#
LNR?
LNR=x
(see Description of
Arguments)
LNB DC
Power
Control
LPS =
1 byte, value
of 0 thru 3
Command or Query.
Sets or returns LNB DC Power Supply Control in the form x, where:
0 = OFF
1 = 13V LNB Voltage
2 = 18V LNB Voltage
3 = 24V LNB Voltage
LPS=
LPS?
LPS*
LPS#
LPS?
LPS=x
(see Description of
Arguments)
LNB Low
Current Limit
LNL =
3 bytes
Command or Query.
Sets or returns Low Current Limit in the form xxx, where:
xxx = value from 0 to 500 mA.
LNL=
LNL?
LNL*
LNL#
LNL?
LNL=xxx
(see Description of
Arguments)
LNB High
Current Limit
LNH =
3 bytes
Command or Query.
Sets or returns High Current Limit in the form xxx, where:
xxx = value from 0 to 500 mA.
LNH=
LNH?
LNH*
LNH#
LNH?
LNH=xxx
(see Description of
Arguments)
LNB Current N/A
4 bytes
Query only.
Returns the LNB Current Limit in the form xxxx, where:
xxxx = value in mA.
EXAMPLE: <0/LNC?
>0000/LNC=0500
LNC#
LNC?
LNC=xxxx
(see Description of
Arguments)
LNB Voltage N/A
4 bytes
Query only.
Returns the LNB Voltage in the form xx.x, where:
xx.x = value in volts.
EXAMPLE: <0/LNC?
>0000/LVO=12.0
LVO#
LVO?
LVO=xx.x
(see Description of
Arguments)