Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–43

(CONFIG: IP) Addresses IP:

To configure the IP Address for the Ethernet M&C J4 | MGMT port: Use the   arrow keys to

select a digit, and then use the  arrow keys to change that digit. Press ENTER.

(CONFIG: IP) AddressesMAC:

The unit MAC address is read-only and is not selectable or editable.

(CONFIG: IP) Addresses Gateway:

The Gateway Address is the default next hop address used by the M&C to send traffic to the

Ethernet M&C J4 | MGMT port when sending a datagram to an IP address outside of its subnet

mask or Address/Range. This address must be defined within the M&C’s subnet address/range.

Use the   arrow keys to select a digit, and then use the  arrow keys to change that digit.

Press ENTER.

6.2.2.8.2 (CONFIG: IP) SNMP

SNMP:

Communities Traps

()

Use the   arrow keys to select a parameter. Press ENTER.

(CONFIG: IP) SNMP Communities

SNMP Communities:

Read Write

()

Use the   arrow keys to select a parameter. Press ENTER.

(CONFIG: IP) SNMP Communities Read

SNMP Read Community:

Public (20 chars) ()

On the bottom line – Use the   arrow keys to select the alphanumeric character to

edit, and then use the  arrow keys to edit that character.

Note that only the first 20 characters on the bottom line are available. All printable ASCII

characters are available with the exception of the backslash ‘/’ (ASCII code 92) and tilde

‘~’ (ASCII code 126).

Press ENTER once you compose the SNMP Read Community string. All trailing spaces