Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–49

Type

Alarm

State

Unit

(cont.)

MEO ACU Comms

The modem has been set to run in MEO mode and the communication

between the remote Tx/Rx modem and the ACU is timing out or is getting a

corrupt / unexpected response.

Ethernet Link Down

One or more of the Modem's Gig-E Ethernet ports (J5, J6, J7) is enabled

but the modem does not detect any connection to another device (switch /

router / PC etc.).

Tx

(Transmit)

Internal DAC Clk PLL

The modem's internal DAC clock out of range or has failed

Internal Tx LO PLL

The modem's internal Tx clock out of range or has failed

PIIC1 Sym Clk PLL

A PIIC interface has been selected but the symbol clock rate that is being

derived from the data does not match the modem SR programmed.

PIIC2 Sym Clk PLL

A PIIC interface has been selected but the symbol clock rate that is being

derived from the data does not match the modem SR programmed.

PIIC1 Input Signal Low An OC-3 data interface was selected but the optical SFP module has

determined that the optical signal level is low.

PIIC2 Input Signal Low An OC-3 data interface was selected but the optical SFP module has

determined that the optical signal level is low.

Rx

(Receive)

Demod Unlocked

Demod is not locked to a signal.

Rx Level

Receive Power Level has tripped AGC alarm point.

CnC Unlocked

Carrier-in-Carrier is enabled but not locked.

Internal ADC Clk PLL

The modem's internal ADC clock out of range or has failed

EsNo Threshold

Receive EsNo is below configured alarm point.

Internal Rx LO PLL

Receive Phase Lock Loop fault.

PIIC1 Buffer Overflow A PIIC interface has been selected but the data rate coming into the PIIC

card exceeds the expected data rate of the user configured PIIC data rate.

PIIC1 Buffer Underflow

A PIIC interface has been selected but the data rate coming into the PIIC

card is less than the expected data rate of the user configured PIIC data

rate.

PIIC1 Buffer CLK PLL

A PIIC interface has been selected but the data rate coming into the PIIC

card is either too high, too low or has too much jitter to generate a

consistent clock for the modem

PIIC2 Buffer Overflow A PIIC interface has been selected but the data rate coming into the PIIC

card exceeds the expected data rate of the user configured PIIC data rate.

PIIC2 Buffer Underflow

A PIIC interface has been selected but the data rate coming into the PIIC

card is less than the expected data rate of the user configured PIIC data

rate.

PIIC2 Buffer CLK PLL

A PIIC interface has been selected but the data rate coming into the PIIC

card is either too high, too low or has too much jitter to generate a

consistent clock for the modem

Decompress Invalid

The modem is receiving data and there is a mismatch between what the far

end is configured for compression (enable/disable) and the alarmed demod

decompression (enable/disable).

LNB Current

The modem has exceeded the high or low current levels as programmed

by the user.

LNB Voltage

The modem detects that the LNB power connection is either OPEN or

SHORT.

Bad/Missing ACM

Packet

The modem's internal local / distant ACM messaging is either missing or

corrupt.