G.5.4 ACM Operation Using the CDM-760 Serial Remote Control Interface

G.5.4.1 CDM-760 Typical Serial Remote Control Overview

See Chapter 8. SERIAL-BASED REMOTE PRODUCT MANAGEMENT for an in-depth

explanation of the use of remote commands and queries over the CDM-760 Serial

Remote Control Interface.

The CDM-760’s serial remote product management interface is an electrical interface that is

either an EIA-485 multi-drop bus (for the control of multiple devices) or an EIA-232 connection

(for the control of a single device). The interface uses ASCII characters in asynchronous serial

form to transmit data between the Controller (e.g., a User PC) and Target (e.g., the modem and

ODU). This data consists of control and status information, transmitted in packets of variable

length in accordance with the structure and protocol explained in detail in Chapter 8.

The Controller is in charge of the process of monitor and control, and is the only device that is

permitted to initiate, at will, the transmission of data. Targets are only permitted to transmit

when they have been specifically instructed to do so by the Controller.

The exchange of information is transmitted, Controller-to-Target and Target-to-Controller, in

packets’. Each packet contains a finite number of bytes consisting of printable ASCII characters,

excluding ASCII code 127 (DELETE).

In this context, the Carriage Return and Line Feed characters are considered printable. With one

exception, all messages from Controller-to-Target require a response – this will be either to return

data that has been requested by the Controller, or to acknowledge reception of an instruction to

change the configuration of the Target.

Controller-to-Target (Issued Command or Query)

Start of Packet Target Address

Address

Delimiter

Instruction

Code

Code Qualifier

Optional

Arguments

End of Packet

<

ASCII Code 60

(1 character)

0000 (default)

(4 characters)

/

ASCII Code 47

(1 character)

(3 characters)

= or ?

ASCII Codes 61

or 63

(1 character)

(n characters)

Carriage Return

ASCII Code 13

(1 character)

Packet “issued command” example: <0000/TMC = 10[cr]

Packet “issued query” example:

<0000/TMC?[cr]

Target-to-Controller (Response to Command or Query)

Start of Packet Target Address

Address

Delimiter

Instruction

Code

Code Qualifier

Optional

Arguments

End of Packet

>

ASCII Code 62

(1 character)

0000 (default)

(4 characters)

/

ASCII Code 47

(1 character)

(3 characters)

= , ?, !, *, #, ~

(ASCII Codes

61, 63, 33, 42,

35, or 126)

(1 character)

(n characters)

Carriage Return

ASCII Code 13

(1 character)

Packet example – response received for issued query: >0000/TMC = 10[cr][lf]