Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Software

Boot From

Image

SBS =

1 byte, value

of 1 or 2

Command or Query.

Sets or returns which bulk firmware image to boot from, in the form x, where:

1 = Firmware is Image #1

2 = Firmware is Image #2

EXAMPLE: <0/SBS=1 (selects Image 1 Firmware)

SBS=

SBS?

SBS*

SBS#

SBS?

SBS=x

(see Description of

Arguments)

Current

Software

Image

N/A

1 byte, value

of 1 or 2

Query only.

Returns the active software image in the form x, where:

1 = Bulk Image #1 currently active

2 = Bulk Image #2 currently active

N/A

IMG?

IMG=x

(see Description of

Arguments)

Circuit ID

String

CID =

4 to 32 bytes Command or Query.

Sets or returns the user-defined Circuit ID string, selects 4 to 32 characters in length.

Valid characters include: [Space] ( ) * + – . / 0 thru 9 and A thru Z

CID=

CID?

CID*

CID#

CID?

CID=x

(see Description of

Arguments)

Date

DAY =

6 bytes

Command or Query.

Sets or returns a date in the form ddmmyy (European format), where

dd = day of the month (01- 31)

mm = month (01-12)

yy = year (00-99)

EXAMPLE: <0/DAY=240457 (April 24, 2057)

DAY=

DAY?

DAY*

DAY#

DAY?

DAY=ddmmyy

(see Description of

Arguments)

Time

TIM =

6 bytes

Command or Query.

Sets or returns the time from midnight in the form hhmmss, where:

hh = hours (00-23)

mm = minutes (00-59)

ss = seconds (00-59)

EXAMPLE: <0/TIM=231259 (23 hours:12 minutes:59 seconds)

TIM=

TIM?

TIM*

TIM#

TIM?

TIM=hhmmss

(see Description of

Arguments)

External

Frequency

Reference

EFR =

1 byte, value

of 0 thru 5

Command or Query.

Sets or returns the External Frequency Reference in the form x, where:

0 = Internal 10MHz (DEFAULT)

1 = External 1 MHz

2 = External 2 MHz

3 = External 5 MHz

4 = External 10 MHz

5 = Internal 10MHz plus output (this means that the Reference is available on the “J8 | EXT REF” rear panel

connector (connector LED indicates when ON).

EXAMPLE: <0/EFR=1 (selects External 1MHz)

EFR=

EFR?

EFR*

EFR#

EFR?

EFR=x

(see Description of

Arguments)

Adjustment

for Internal

10MHz High-

stability

Reference

ADJ =

4 bytes

Command or Query.

Sets or returns fine adjustment of the Internal 10MHz Reference on the High-Stability Frequency Reference

module in the form sddd, where:

s = sign (+ or –)

ddd = value from 000 to 999.

ADJ=

ADJ?

ADJ*

ADJ#

ADJ?

ADJ=sddd

(see Description of