AUPC Parameters

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Power Control

State (AUPC)

PCS =

1 byte, value

of 0 or 1

Command or Query.

Sets or returns Power Control State in the form x, where:

0 = Manual

1 = AUPC (Automatic Power Control)

EXAMPLE: <0/PCS=1 (enables AUPC)

PCS=

PCS?

PCS*

PCS#

PCS?

PCS=x

(see Description of

Arguments)

AUPC Target

Es/No

ATE =

4 bytes

Command or Query.

Sets or returns the Target Es/No in the form xx.x, where:

xx.x = from 00.0 dB to 23.5 dB.

EXAMPLE: <0/ATE=12.5 (sets Target Es/No to 12.5 dB)

ATE=

ATE?

ATE*

ATE#

ATE?

ATE=xx.x

(see Description of

Arguments)

AUPC Nominal

Power Value

ANP =

5 bytes

Command or Query.

Sets or returns the Nominal Power Value in the form sxx.x, where:

s = sign (+ or -)

xx.x = Value in the range from -40.0 dBm to 0.0 dBm (L-Band) or -25.0 dBm to 0.0 dBm (70/140 MHz).

EXAMPLE: <0/ANP=-12.5 (sets Nominal Value to -12.5 dBm)

ANP=

ANP?

ANP*

ANP#

ANP?

ANP=sxx.x

(see Description of

Arguments)

AUPC Power

Range

APR =

4 bytes

Command or Query.

Sets or returns the Power Range in the form xx.x, where

xx.x = Value in the range from 0.0 dBm to 40.0 dBm (L-Band) or 0.0 dBm to 25.0 dBm (70/140 MHz).

EXAMPLE: <0/APR=25.0 (sets Power Range to 25.0 dBm)

APR=

APR?

APR*

APR#

APR?

APR=xx.x

(see Description of

Arguments)

AUPC Remote

Carrier Loss

Action

RCL =

1 byte, value

of 0 or 1

Command or Query.

Sets or returns Remote Carrier Loss Action in the form x, where:

0 = Goto Nominal Power Value

1 = Goto Max Power Value (Nominal Value + Range)

EXAMPLE: <0/APR=25.0 (sets Power Range to 25.0 dBm)

RCL=

RCL?

RCL*

RCL#

RCL?

RCL=x

(see Description of

Arguments)

AUPC Local

Carrier Loss

Action

LCL =

1 byte, value

of 0 or 1

Command or Query.

Sets or returns Local Carrier Loss Action in the form x, where:

0 = Goto Nominal Power Value

1 = Goto Max Power Value (Nominal Value + Range)

EXAMPLE: <0/LCL=0 (sets Nominal Power)

LCL=

LCL?

LCL*

LCL#

LCL?

LCL=x

(see Description of

Arguments)