7 aupc parameters – Comtech EF Data CDM-760 User Manual
Page 261

Serial-based Remote Product Management
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
8–27
8.5.7
AUPC Parameters
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Power Control
State (AUPC)
PCS =
1 byte, value
of 0 or 1
Command or Query.
Sets or returns Power Control State in the form x, where:
0 = Manual
1 = AUPC (Automatic Power Control)
EXAMPLE: <0/PCS=1 (enables AUPC)
PCS=
PCS?
PCS*
PCS#
PCS?
PCS=x
(see Description of
Arguments)
AUPC Target
Es/No
ATE =
4 bytes
Command or Query.
Sets or returns the Target Es/No in the form xx.x, where:
xx.x = from 00.0 dB to 23.5 dB.
EXAMPLE: <0/ATE=12.5 (sets Target Es/No to 12.5 dB)
ATE=
ATE?
ATE*
ATE#
ATE?
ATE=xx.x
(see Description of
Arguments)
AUPC Nominal
Power Value
ANP =
5 bytes
Command or Query.
Sets or returns the Nominal Power Value in the form sxx.x, where:
s = sign (+ or -)
xx.x = Value in the range from -40.0 dBm to 0.0 dBm (L-Band) or -25.0 dBm to 0.0 dBm (70/140 MHz).
EXAMPLE: <0/ANP=-12.5 (sets Nominal Value to -12.5 dBm)
ANP=
ANP?
ANP*
ANP#
ANP?
ANP=sxx.x
(see Description of
Arguments)
AUPC Power
Range
APR =
4 bytes
Command or Query.
Sets or returns the Power Range in the form xx.x, where
xx.x = Value in the range from 0.0 dBm to 40.0 dBm (L-Band) or 0.0 dBm to 25.0 dBm (70/140 MHz).
EXAMPLE: <0/APR=25.0 (sets Power Range to 25.0 dBm)
APR=
APR?
APR*
APR#
APR?
APR=xx.x
(see Description of
Arguments)
AUPC Remote
Carrier Loss
Action
RCL =
1 byte, value
of 0 or 1
Command or Query.
Sets or returns Remote Carrier Loss Action in the form x, where:
0 = Goto Nominal Power Value
1 = Goto Max Power Value (Nominal Value + Range)
EXAMPLE: <0/APR=25.0 (sets Power Range to 25.0 dBm)
RCL=
RCL?
RCL*
RCL#
RCL?
RCL=x
(see Description of
Arguments)
AUPC Local
Carrier Loss
Action
LCL =
1 byte, value
of 0 or 1
Command or Query.
Sets or returns Local Carrier Loss Action in the form x, where:
0 = Goto Nominal Power Value
1 = Goto Max Power Value (Nominal Value + Range)
EXAMPLE: <0/LCL=0 (sets Nominal Power)
LCL=
LCL?
LCL*
LCL#
LCL?
LCL=x