Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–67

Select On to enable a high stability 10MHz reference clock with ±0.06 ppm on the rear

panel J9 | L-BAND RX IN Type ‘N’ connector.

(ODU: LNB:PwrSupply+Ref) PSU-and-10MHz Alarm limits

The CDM-760 constantly monitors the LNB power supply source. Use this selection to

define an alarm range that alerts you to problems with the LNB.

On the bottom line, first use the   arrow keys to select a digit to edit, and then use

the  arrow keys to change that digit. Press ENTER. Valid settings are:

Range

Step Size

Minimum

Maximum

000 mA

500 mA

1 mA

6.2.7.2 (ODU: LNB:PwrSupply+Ref) PSUmonitor

LNB Power Supply [On]

274mA, 18.2V

The top line for this read-only screen shows whether the LNB is On or Off:

If the LNB is On, the bottom line of this screen displays the present current and voltage readings

for the LNB Power Supply.

If the LNB is Off, the bottom line displays 0000mA, 00.0V.

Press ENTER or CLEAR to return to the previous menu.

6.2.8 SELECT: FAST

Chapter 5. FAST ACTIVATION PROCEDURE

FAST: Options Demo-Mode CnC ()

Baseboard S/N 123456789 HW RevXX.XX

FAST (Fully Accessible System Topology) allows you to enable new options in the modem.

Contact Comtech EF Data Product Support to purchase a FAST Option and acquire the

associated FAST Access Code.

The bottom line displays the modem’s 9-digit “Baseboard S/N” – you will need to provide this

information to Comtech EF Data Product Support when ordering FAST feature upgrades.

On the top line, use the   arrow keys to select a parameter. Press ENTER.