beautypg.com

Comtech EF Data CDM-760 User Manual

Page 173

background image

Ethernet-based Remote Product Management

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

7–15

Enter an IP Gateway destination address. If a response destination IP address is outside of

the CMD-760 M&C subnet, then the CDM-760 forwards M&C responses to this address.

Enter an IP Address/Range (

IP address and subnet mask) for the CDM-760 M&C card.

System Account Access Information

At the time of publication, the "SMTP Server", "SMTP Domain Name", and "SMTP

Destination" text fields are non-functional.

Enter a Read-only, Read/Write, or Admin Name and Password. A name or password can be

any alphanumeric combination with a maximum length of 10 characters. The factory default

names/passwords are as follows:

o

Read-only

monitor/1234

o

Read/Write

opcenter/1234

o

Admin

comtech/comtech

Host Access List

The Host Access List allows you to define a list of remote client PCs which can connect to the

CDM-760 via HTTP and SNMP.

Enter an IP (#) / Mask (IP address and a subnet mask) for each Access List entry.

For example, if you want to grant access to a remote client PC with an IP Address of

10.10.10.1, and any PC on a subnet of 192.168.10.xxx, then you would define the Access List

as:

IP 1 / Mask:

10.10.10.1/32

IP 2 / Mask:

192.168.10.0/24

Make sure ‘IP 3 / Mask’ and ‘IP 4 / Mask’ are not 0.0.0.0/0. An entry with

0.0.0.0/0 allows access to any PC.

Use the Access List drop-down list to select Enable or Disable. When disabled, any client PC

may connect via HTTP and SNMP.

Click [Submit Admin] to save.