Comtech EF Data CDM-760 User Manual
Page 115

Front Panel Operation
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
6–29
Step
Task
5
Configure one PIIC interface, or any combination of the GbE interfaces, to
operate.
6
Use the arrow keys to select the CONFIG: Tx → Data → Tx Data Rate
menu. Make sure the Tx Data Rate MIN_DR variable displays “000000.000”.
After the Tx side of the link is configured, do these next steps to configure
the Rx side for Single Stream or MultiStream Mode:
Step
Task
1
Configure the Rx Symbol Rate.
Use the arrow keys to select the CONFIG: Rx→ Data→ Rx Symbol Rate
menu. Set the Rx Symbol Rate to match the far side modem Tx Symbol Rate.
2
Set the Rx GoldCode (Gold-n Index Code).
Use the arrow keys to select the CONFIG: Rx→ Freq menu. Set the Rx
GoldCode to match the far side modem Tx GoldCode.
3
Make sure that the interfaces selected during the Tx configuration are
configured and operating properly.
6.2.2.4.2 (CONFIG: INTF) (GBEIX)
1)
The GBEIX menus are nonfunctional when the optional High-Speed Packet
Processor is installed and enabled. Functionality is available when Packet
Processor operation is disabled or when the standard PIIC slots card is installed.
2)
M&C for the High-Speed Packet Processor is provided on the CDM-760 HTTP
Interface. See Chapter 7. ETHERNET-BASED REMOTE PRODUCT MANAGEMENT
for full information about using this interface for Packet Processor operations.
GBEIX: Type:Auto Status:NoLink ()
FlowControl:Disabled Learning:Disabled
Where the letter ‘X’ in GBEIX represents the base unit interface – GBEI1 (J5 | DATA port) or
GBEI2 (J6 | DATA port): Use the arrow keys to select a parameter. Press ENTER.
(CONFIG: INTF) (GBEIX) Type
Take care when using this menu, as a mismatch can cause random packet loss and
connection drops.
Use the arrow keys to select a port configuration parameter. Press ENTER.