Appendix D

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

D–4

Figure D-3. CDM-760 Switching – InBand “Disabled”

InBand Enabled – Figure D-4 shows the internal Ethernet architecture for the CDM-760

when InBand is “Enabled”. In other circumstances it may be advantageous to allow the M&C

traffic and User Data traffic to co-exist in order to monitor and control a remote site without

the need for an external switch. Setting InBand as “Enabled” facilitates this configuration.

Figure D-4. CDM-760 Architecture – InBand “Enabled”

With this configuration, you must take care not to create an Ethernet loop (Figure D-5).

Ethernet loops happen when an Ethernet frame can get to the same switch or modem on

more than one port. See Sect. D.3.1 for more information.