Installation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

2–2

Once opened, inspect the shipment:

Step

Task

1

Keep all shipping materials.

2

Check the packing list to make sure the shipment is complete.

3

Inspect the equipment for damage. If damage exists, immediately contact the carrier

and Comtech EF Data to submit a damage report.

4

Read the manual.

2.2

Install the Unit Into a Rack Enclosure

Install the CDM-760 in its assigned position in the rack enclosure (Figure 2-2).

Use, as required:

• A standard rack-mounted shelf;

• User-supplied screws to secure the front panel to the rack enclosure threaded front

mounting rails;

• Comtech EF Data’s optional KT-0000168 (4”) or KT-0000195 (10”) Rear Support Brackets Kit

(Figure 2-3).

• Comtech EF Data’s optional FP/SL0006 Bearingless Rack Slide Set (Figure 2-4).

For information about custom rack enclosures, contact Comtech EF Data Product Support.

CAUTION – CORRECT GROUNDING PROTECTION IS REQUIRED TO PREVENT PERSONAL

INJURY AND EQUIPMENT DAMAGE.

You must make sure the ground stud on the rear panel of the unit is always connected

to the protective earth.

SUFFICIENT AIR VENTILATION IS REQUIRED.

Make sure there is adequate air ventilation clearance inside the enclosure, especially

at the side. In a rack system where there is high heat discharge, provide forced-air

cooling with top- or bottom-mounted fans or blowers.

MAXIMUM AIR TEMPERATURE.

Make sure the air temperature inside the enclosure

never

exceeds 50°C (122°F).