beautypg.com

3 snmp traps – Comtech EF Data CDM-760 User Manual

Page 162

background image

Ethernet-based Remote Product Management

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

7–4

7.2.3 SNMP Traps

The modem has the ability to send out SNMP traps when an alarm or a fault occurs in the modem.

These include unit, Tx, Rx, and ODU faults. A trap is sent both when a fault occurs and is cleared.

The modem supports both SNMPv1 traps and SNMPv2 notifications. You may configure the

modem to send either style by using the CDM760SNMPTrapVersion OID:

The CDM-760 supports the following MIB2 SNMPv1 traps / SNMPv2 notifications:

MIB2 SNMPv1 trap: Authentication Failure

5

MIB2 SNMPv2 notifications: Authentication Failure

1.3.6.1.6.3.1.1.5.5

The CDM-760 supports the following Alarms and Faults SNMPv1 traps:

cdm760UnitAlarmV1

6247600

cdm760TxTrafficAlarmV1

6247601

cdm760RxTrafficAlarmV1

6247602

cdm760TrapStoredEventAlarm

6247603

cdm760RedundancySwitch

6247604

The CDM-760 supports the following Alarms and Faults SNMPv2 notifications:

cdm760TrapUnitAlarm

1.3.6.1.4.1.6247.77.2.1.1.1

cdm760TrapTxAlarm

1.3.6.1.4.1.6247.77.2.1.1.2

cdm760TrapRxAlarm

1.3.6.1.4.1.6247.77.2.1.1.3

cdm760TrapStoredEventAlarm

1.3.6.1.4.1.6247.77.2.1.1.4

cdm760RedundancySwitch

1.3.6.1.4.1.6247.77.2.1.1.5