beautypg.com

Comtech EF Data CDM-760 User Manual

Page 156

background image

Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–70

6.2.8.3 (FAST:) CnC

FractionalCnC:Time Remaining: 90:00:00:00

Time Remaining Refills In 364:23:59:31

Full CnC License is installed.

Fractional CnC is common in 1:1 or 1:N redundancy systems where the primary modem is

running fully operational (i.e., FAST-activated) CnC, and the backup modem(s) has FAST-

activated Fractional CnC.

Fractional CnC allows 90 full calendar days of CnC usage in a calendar year. This lowers the cost

of the modem but does not allow for constant, round-the-clock CnC operation.

As per the previous screen examples, if Fractional CnC is not installed in the CDM-760, the

modem displays a message that no CnC license is installed and provides “time remaining” and

“time remaining refill” timers; or that a Full CnC license is installed and the screen displays no

timers. Note the following:

FractionalCnC: Time Remaining – This is the amount of time, in the form dd:hh:mm:ss

(days: hours:minutes:seconds), that that the modem can be run in CnC mode. This counter

decrements under the following conditions:

o

The modem has a FAST-activated Fractional CnC license

o

The modem is powered ON

o

The modem’s Tx is ON

o

The modem is in standalone mode or in 1:1 redundancy configuration and is Online

o

The modem is NOT in Demo Mode. If the timer reaches 00:00:00:00, the modem will

turn its Tx Off and the circuit will be down.

Time Remaining Refills In – This is the calendar year counter that resets FractionalCnCTime

Remaining to its 90 full days of CnC usage when it reaches 00:00:00:00. This counter

continually decrements and even accounts for time when the modem is powered Off. Once

this timer fully decrements, Time Remaining Refills In once again resets to 365:00:00:00 and

immediately begins to decrement.

Fractional CnC:Time Remaining cannot be reset or refilled in the field. Once

the timer has run out, your only options are to:

1)

Upgrade the modem to fully functional CnC.