Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–18

Valid settings are:

IF Frequency

Total Output Power Range of CDM-760

Minimum

Maximum

Step Size

70 / 140 MHz (50-180 MHz in 100 Hz Steps)

0 dBm

-25 dBm

0.1 dBm

L-Band (950-2150 MHz in 100 Hz steps)

0 dBm

-40 dBm

0.1 dBm

(CONFIG: Tx) Power AUPC Range

The Range defines how much the modem is permitted to increase the Tx output level

beyond the Nominal level while under AUPC control. Set the Range to accommodate

any output power level the modem allows for under its current mode of operation, on

the condition that the Nominal + Range sum does not exceed the total output power

range of the modem.

Use the  arrow keys to set the value. Press ENTER. Valid settings are:

Range

Step Size

Minimum

Maximum

0.00 dB

40.0 dB

0.1 dB

6.2.2.2.5 (CONFIG: Tx) ACM (Adaptive Coding and Modulation)

Appendix G. ADAPTIVE CODING

AND

MODULATION (ACM) OPTION

ACM Config: Min/Max-ModCod Unlock-Action

Target-EsNo-Margin Degradation

()

Use the   arrow keys to select a parameter. Press ENTER.

(CONFIG: Tx) ACM ConfigMin/Max-ModCod

To force the system to run at a fixed ModCod, set the Min and Max ModCod to

equal values.

Other FAST options that are installed for Modulation and Symbol Rate may limit the

Max ModCod value.

Min Modcod: QPSK 1/2

Max Modcod: 32APSK 9/10

Set the ModCod range to configure the modem’s transmit capability.

Use the   arrow keys to select Min Modcod (top line) or Max Modcod (bottom line). Press

ENTER. Then, use the  arrow keys to set the ModCod. Press ENTER.