beautypg.com

Comtech EF Data CDM-760 User Manual

Page 263

background image

Serial-based Remote Product Management

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

8–29

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

PIIC

Mode Select

ETS =

2 bytes

Command or Query.

Sets or returns the PIIC interface card mode in the form sm, where:

s = Interface Slot, where:

1 = Slot 1

2 = Slot 2

m = Mode, where:

For G.703 PIIC module:

0 = NONE

1 = E3

2 = T3

3 = STS1

NOTE: G703 PIIC settings other than none will also set the selected G.703 data rate. The unit will adjust

the symbol rate based on the modulation type, code rate, framing, and pilots to keep the selected data rate

For OC3 PIIC module:

0 = NONE

1 = OC3/STM-1

NOTE: OC3 PIIC settings other than none will also set the modem data rate to 155.52 Mbps. The unit will

adjust the symbol rate based on the modulation type, code rate, framing, and pilots to keep the selected

data rate.

NOTE: Commands are valid only with the appropriate PIIC interface as indicated above. In addition, the

following is true for various cards.

EXAMPLE: <0/ETS=11 (sets G.703 PIIC module in Slot 1 to E3 mode; sets OC3 PIIC module in Slot 1 to

OC3/STM-1 mode)

MultiStream and Single Stream Modes:

To enable MultiStream Mode:

1. Disable all PIIC Interfaces.

2. Enable one or more Gigabit Ethernet Interfaces.

3. Set the SR, ModCod, etc. to meet your requirements.

4. Enable PIIC 1 or PIIC 2 or both interfaces.

To enable PIIC1 or PIIC2 in synchronous interface mode:

1. Disable all PIIC Interfaces.

2. Disable all Gigabit Ethernet Interfaces.

3. Enable PIIC1 or PIIC2.

NOTE: GBEI 1, GBEI 2 and Optical Ethernet must all be disabled before a PIIC can operate in a

synchronous mode.

ETS=

ETS?

ETS *

ETS #

ETS?s

ETS=sm

(see Description of