Comtech EF Data CDM-760 User Manual
Page 372

Appendix H
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
H–6
4)
On the bottom line of the CID screen, create an Administrative contact (telephone)
number:
A. Use the arrow keys to navigate to Telephone. Press ENTER to proceed:
CID Telephone Number:
()
...........+15555555555 ..........
B. On the bottom line, use the arrow keys to select an alphanumeric character to edit,
and then use the arrow keys to change that character. Press ENTER.
You may use the following characters:
[Space], 0-9, +, and x
Use the CID Telephone Number to provide a valid emergency contact number to call to
resolve operational issues – e.g., in case the modulator’s Tx output is causing interference
on the satellite. Providing this phone number allows a satellite operator to quickly call the
person(s) responsible for correcting any issues.
5)
On the bottom line of the CID screen, create a CID Custom Message:
A. Use the arrow keys to navigate to Message. Press ENTER to proceed:
B. On the bottom line, use the arrow keys to select an alphanumeric character to edit,
and then use the arrow keys to change that character. Press ENTER to save.
CarrierID:Custom message: ()
----------- Comtech EF Data --------------
You may use the following characters:
[Space], 0-9, +, and x
Use the CID Custom Message to provide additional information that may be useful in
resolving operational issues, e.g., to quickly resolve interference.