beautypg.com

Comtech EF Data CDM-760 User Manual

Page 83

background image

FAST Activation Procedure

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

5–3

a) Use the ◄►arrows keys to select OPTIONS, and then press ENTER:

FAST 1: Set View 2: Set View
OPTIONS 3: Set View (

◄ ►▲▼)

b) Use the ◄►arrows keys to select View for the desired register #, and then press

ENTER.

c) Use the ▲▼arrow keys to scroll through the list of available FAST options. Options are

identified as ‘Installed’ or ‘Not Installed’. Any option listed as ‘Not Installed’ may be

purchased as a FAST upgrade.

3. Contact Comtech EF Data Product Support to order features:

• Provide the modem’s 9-digit Baseboard Serial Number to the representative.

• Identify and purchase the desired FAST option(s).

• Obtain the invoice, the register-specific 20-digit FAST Access Code(s), and the FAST

option activation instructions.

When you purchase a FAST Access Code from Comtech EF Data, it will be for a

specific option register

. The FAST options are linked to the three option

registers explained in Sect. 5.2.

4. Enter the FAST Access Code(s):

a) Press CLEAR to return to the SELECT: FAST Options (Register #) Set menu.

b) Use the arrow keys (◄ ►▲▼) to carefully enter your register-specific 20-character

FAST Access Code.

FAST: Set register1: Enter code below
00000000000000000000 then [ENTER] (

◄ ►▲▼)

c) Press ENTER to execute the FAST upgrade.

The modem responds with “Configured Successfully” if the FAST upgrade is accepted;

the modem then resets to its newly-incorporated default configuration.

However, if an invalid code is entered, the following message displays:

Failure to configure. Re-enter code.
88888888888888888888 then [ENTER] (

◄ ►▲▼)

Repeat the FAST Access Code entry procedure. Should the code entry error persist,

contact Comtech EF Data Product Support for further assistance.