beautypg.com

Comtech EF Data CDM-760 User Manual

Page 247

background image

Serial-based Remote Product Management

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

8–13

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Tx Alpha

Rolloff

TAR =

1 byte, value

of 0 thru 5

Command or Query.

Sets or returns Tx Alpha Rolloff in the form x, where:

0 = 20%

1 = 25%

2 = 35%

3 = 5% (only available when NET>0)

4 = 10% (only available when NET>0)

5 = 15% (only available when NET>0)

EXAMPLE: <0/TAR=0 (selects a Tx Alpha Rolloff of 20%)

TAR=

TAR?

TAR*

TAR#

TAR?

TAR=x

Tx Gold Code

Sequence

Index

TGS =

6 bytes

Command or Query.

Sets or returns Tx Gold Code Sequence Index in the form xxxxxx, where:

Gold Code Sequence Index = 000000 to 262141

EXAMPLE: <0/TGS=189063

TGS=

TGS?

TGS*

TGS#

TGS?

TGS=xxxxxx

Tx Pilot

TPI =

1 byte, value

of 0 or 1

Command or Query.

Sets or returns Tx Pilot in the form x, where:

0 = Off

1 = On

NOTES:

1) CEFD recommends that you use Pilots when running any 16-APSK, 32-APSK, or 64-APSK ModCod.

2) Pilots are recommended when the symbol rate is below 5000 ksps.

EXAMPLE: <0/TPI=0 (selects Pilot Off)

TPI=

TPI?

TPI*

TPI#

TPI?

TPI=x

Tx Power

Level

TPL =

5 bytes

Command or Query.

Sets or returns Tx Output power level (dBm), in 0.1 dB steps, in the form sxx.x, where:

s = sign (+ or -)

xx.x = power level (dBm) from 0 to -25 dBm (70/140 MHz) or 0 to -40 dBm (L-Band)

EXAMPLE: <0/TPL=-13.4

TPL=

TPL?

TPL*

TPL#

TPL?

TPL=sxx.x

(see Description of

Arguments)

Tx Carrier

State

TXO =

1 byte, value

of 0 or 1

Command or Query.

Sets or returns Tx Carrier State in the form x, where:

0 = OFF due to front panel or remote control command

1 = ON

EXAMPLE: <0/TXO=1 (Tx Carrier ON)

TXO=

TXO?

TXO*

TXO#

TXO?

TXO=x

(see Description of

Arguments)