beautypg.com

Comtech EF Data CDM-760 User Manual

Page 111

background image

Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–25

6.2.2.3.4 (CONFIG: Rx) EsNo

Receive EsNo Alarm Point = -03.0 dB

()

Use the   arrow keys to select a digit, and then use the  arrow keys to change that digit.

Press ENTER.

If the Rx Es/No falls below this value and the fault is NOT masked, the modem

generates a receive traffic fault.

6.2.2.4 CONFIG: Intf (Configure Interface)

Appendix C. OPTIONAL PIIC (PLUG-IN INTERFACE CARD) MODULES

Appendix F. OPTIONAL HIGH-SPEED PACKET PROCESSOR

1)

The acronyms “GbE” and “GigE” both refer to “Gigabit Ethernet.” They are used

interchangeably throughout the front panel interface.

2)

The selections here will vary, depending both on the presence of the PIIC or

High-Speed Packet Processor hardware options and whether Single Stream or

MultiStream Operating Mode is in use.

When the PIIC interface slot card is installed:

GBEI1 GBEI2 Optical PIIC1 PIIC2

Auto Off NONE G703-E3 G703-OFF

When the optional High-Speed Packet Processor card is installed:

GBEI1 GBEI2 Optical PacketProcessor

Off Off NONE Enabled

Use this screen to see the installation status and configured state of each interface. This screen

consists of five columns when the standard PIIC slot card is installed or four columns when the

optional High-Speed Packet Processor card is installed.

The top line of each column displays an available interface; the screen shows the installation

and configuration status for that interface directly below.

On the bottom line – Use the   arrow keys to select a configurable interface. Press ENTER.

Table 6-5 provides detailed information for the menu selections and their conditional availability.