Comtech EF Data CDM-760 User Manual
Page 152

Front Panel Operation
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
6–66
6.2.6.8.2 (Utility: Firmware Images) Select
Current Active Image is #1
Next Reboot, will use Image: #1
The read-only top line shows the active firmware image. This example shows Image #1 as the
Current Active Image.
On the bottom line – Use the arrow keys to select the standby image (in this example, Image
#2) if desired. Press ENTER. You are then prompted to reboot the unit.
6.2.7 SELECT: ODU (Outdoor Unit)
The BUC:PwrSupply+Ref and FSK-control selections are reserved for future use and
are non-operational at this time.
ODU: BUC:PwrSupply+Ref
LNB:PwrSupply+Ref FSK-control ()
Use the arrow keys to select LNB: PwrSupply+Ref. Press ENTER.
6.2.7.1 (ODU:) LNB:PwrSupply+Ref
LNB control/monitor:
PSU-and-10MHz PSUmonitor ()
Use the arrow keys to select a parameter. Press ENTER.
(ODU: LNB:PwrSupply+Ref) PSU-and-10MHz
LNB: Voltage=Off 10MHz=Off (Off,On)
Alarm limits, from 000 to 500 mA
()
Use the arrow keys to select a parameter. Press ENTER.
(ODU: LNB:PwrSupply+Ref) PSU-and-10MHz Voltage
Use the arrow keys to select Off, 13V DC, 18V DC, or 25V DC. Press ENTER.
Any setting other than Off configures the rear panel J9 | L-BAND RX IN Type ‘N’
connector.
(ODU: LNB:PwrSupply+Ref) PSU-and-10MHz 10MHz
Use the arrow keys to select Off or On. Press ENTER.