beautypg.com

Comtech EF Data CDM-760 User Manual

Page 351

background image

Appendix G

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

G–17

G.4.8 Notes and Recommendations

• CDM-760 ACM operation is designed for point-to-point operation only. Future point to multi-

point operation will be introduced in a later release of the product. ACM operation and

purchased option are required on all modems running the link (two in non-redundant mode

and four in 1:1 redundant mode).

• ACM constitutes a closed-loop control system similar in concept to Automatic Uplink Power

Control (AUPC). It should be remembered that, like all control systems, the speed at which the

system can react is governed by a number of factors, including: the time taken to estimate

Es/No to the required accuracy at the far side demodulator; the transport delay over the

satellite; and the processing of messages and associated action taken at the near side

modulator.

• The ACM controller algorithm that resides in the CDM-760 does not have to switch through

ModCods sequentially – it can change, if needed, directly from ModCod4 to ModCod28 (or

vice versa).

• While ACM can do remarkable things, the fundamentals still apply. The demodulator will not

run at a 16APSK ModCod if the Es/No instantaneously drops to 0dB – the demodulator will

lose lock and the system will recover by switching to ModCod4 (if so configured). The

recommended setting for Minimum ModCod is 4. Comtech EF Data also recommends that

you set the Unlock Action to ‘Go to minimum ModCod’ – this will give the most robust link

availability.

• Running the ACM link with the Target Es/No Margin set to 0dB will give the best utilization

of link power but, in conditions of fast fading, may cause demod unlock events or highly

degraded BER just prior to the switch to a lower ModCod. In order to mitigate this, use a

increase the target Es/No Margin if the fading events are particularly severe and/or frequent.

• The value of Max ModCod may be limited by other FAST codes installed in the CDM-760.

Example: Suppose the 15 Msps FAST option is installed, and the symbol rate is set to 15

Msps; the theoretical maximum data rate would be 52.2 Mbps at ModCod 23.

However, if CnC is being used with a 40 Mbps FAST limit, the ACM Max ModCod will be

limited to ModCod 18, or 38.6 Mbps.

If, for a given symbol rate, it is not possible to set Max ModCod to the desired value, you

should therefore check to determine what other FAST codes may be limiting Max ModCod.

• Es/No is the preferred metric for driving the adaptation – this is the value displayed on the

monitor screens. If you want to convert this to Eb/No then remember that the relationship is

simply Eb/No = Es/No – 10log(Spectral Efficiency).

• To achieve minimum latency, set the WAN buffer to the smallest practical value. The default

setting is 20 ms, and Comtech EF Data recommends keeping it at this level.