Comtech EF Data CDM-760 User Manual
Page 275

Serial-based Remote Product Management
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
8–41
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
BERT Results
All: Total Bit
Errors, Total
Number Of
Bits and
average BER
N/A
23 or 15 bytes Query only.
Returns 3 values, with each parameter is separated by a colon, in the form x.xEx:y.yEy:z.zEz where:
x.xEx = total number of bit errors
yEy = total number of bits
z.zEz = value of the average BER or “No Sync” if no demod lock.
EXAMPLE 1: <0/BRA?
RESPONSE EXAMPLE 1: >0000/BRA=1.0E+03:2.2E+06:1.0E+03 (No Demod Lock)
RESPONSE EXAMPLE 2: >0000/BRA=1.0E+03:2.2E+06 (No Sync)
N/A
BRA?
BRA=x.xEx:y.yEy:z.
zEz
(see Description of
Arguments)
Tx BERT
State
BTX =
1 byte, value
of 0 or 1
Command or Query.
Sets or returns Tx BERT state in the form x, where:
0 = off
1 = on
EXAMPLE: <0/BTX=1 (BERT On)
BTX=
BTX?
BTX*
BTX#
BTX?
BTX=x
(see Description of
Arguments)
BERT Pattern
Sync
N/A
1 byte, value
of 1 or 2
Query only.
Returns the BER Test Pattern Sync Status in the form x, where:
1 = pattern sync
2 = no pattern sync
N/A
RPS?
RPS=X
Tx Baseband
Frames per
ModCod
N/A
Query only.
Return format for each Tx ModCod entry, separated by a colon, in the form x.xE+xx for each entry.
There are 28 total entries when NET=0; 47 total entries when NET=1; and 52 total entries when NET=2.
N/A
ST2?
ST2=(see
Description of
Arguments)
Rx Baseband
Frames per
ModCod
N/A
Query only.
Return format for each Rx ModCod entry, separated by a colon, in the form x.xE+xx for each entry.
There are 28 total entries when NET= 0; 47 total entries when NET=1; and 52 total entries when NET=2.
N/A
ST3?
ST3=(see
Description of
Arguments)
Rx Baseband
Frames
received with
errors per
ModCod
N/A
Query only.
Return format for each Rx ModCod entry, separated by a colon, in the form x.xE+xx for each entry.
There are 28 total entries when NET=0; 47 total entries when NET=1; and 52 total entries when NET=2.
N/A
ST4?
ST4=(see
Description of
Arguments)
Rx Baseband
Frames
discarded
N/A
Query only.
Returns the Rx baseband frames received without errors, but discarded due to the required feature code
not having been purchased. Returns two entries separated by a colon:
First entry = 16 APSK frames discarded
Second = 32 APSK frames discarded.
N/A
ST5?
ST5=(see
Description of
Arguments)