beautypg.com

Comtech EF Data CDM-760 User Manual

Page 275

background image

Serial-based Remote Product Management

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

8–41

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

BERT Results

All: Total Bit

Errors, Total

Number Of

Bits and

average BER

N/A

23 or 15 bytes Query only.

Returns 3 values, with each parameter is separated by a colon, in the form x.xEx:y.yEy:z.zEz where:

x.xEx = total number of bit errors

yEy = total number of bits

z.zEz = value of the average BER or “No Sync” if no demod lock.

EXAMPLE 1: <0/BRA?

RESPONSE EXAMPLE 1: >0000/BRA=1.0E+03:2.2E+06:1.0E+03 (No Demod Lock)

RESPONSE EXAMPLE 2: >0000/BRA=1.0E+03:2.2E+06 (No Sync)

N/A

BRA?

BRA=x.xEx:y.yEy:z.

zEz

(see Description of

Arguments)

Tx BERT

State

BTX =

1 byte, value

of 0 or 1

Command or Query.

Sets or returns Tx BERT state in the form x, where:

0 = off

1 = on

EXAMPLE: <0/BTX=1 (BERT On)

BTX=

BTX?

BTX*

BTX#

BTX?

BTX=x

(see Description of

Arguments)

BERT Pattern

Sync

N/A

1 byte, value

of 1 or 2

Query only.

Returns the BER Test Pattern Sync Status in the form x, where:

1 = pattern sync

2 = no pattern sync

N/A

RPS?

RPS=X

Tx Baseband

Frames per

ModCod

N/A

Query only.

Return format for each Tx ModCod entry, separated by a colon, in the form x.xE+xx for each entry.

There are 28 total entries when NET=0; 47 total entries when NET=1; and 52 total entries when NET=2.

N/A

ST2?

ST2=(see

Description of

Arguments)

Rx Baseband

Frames per

ModCod

N/A

Query only.

Return format for each Rx ModCod entry, separated by a colon, in the form x.xE+xx for each entry.

There are 28 total entries when NET= 0; 47 total entries when NET=1; and 52 total entries when NET=2.

N/A

ST3?

ST3=(see

Description of

Arguments)

Rx Baseband

Frames

received with

errors per

ModCod

N/A

Query only.

Return format for each Rx ModCod entry, separated by a colon, in the form x.xE+xx for each entry.

There are 28 total entries when NET=0; 47 total entries when NET=1; and 52 total entries when NET=2.

N/A

ST4?

ST4=(see

Description of

Arguments)

Rx Baseband

Frames

discarded

N/A

Query only.

Returns the Rx baseband frames received without errors, but discarded due to the required feature code

not having been purchased. Returns two entries separated by a colon:

First entry = 16 APSK frames discarded

Second = 32 APSK frames discarded.

N/A

ST5?

ST5=(see

Description of

Arguments)