Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–63

Use the  arrow keys to select Enable and then press ENTER to execute a diagnostic test on

the front panel LED Indicators and the VFD.

The test run checks each LED Indicator, individually and as a group, while generating a series of

test patterns on the VFD. Normal operations resume upon completion of the test.

6.2.6.5 (Utility:) 1:1

1:1: Manual/Auto Force Status

Use the   arrow keys to select a parameter. Press ENTER

.

(Utility: 1:1) Manual/Auto

1:1 Redundancy: Manual

Use the  arrow keys to select Manual or Auto. Press ENTER. The operational states for 1:1

Redundancy are as follows:

Manual – The currently active modem remains Online regardless of any current or future

faults. Online and Offline (Standby) modems remain in this state until you Force the

switchover.

Auto – The redundancy switch chooses which modem is Online based on fault conditions:


o

If the original Online modem, Unit ‘A’ becomes faulted, then switch occurs to the Offline

modem, Unit ‘B’ only if it is fault-free.

o

Switchover back to Unit ‘A’ occurs only if the Standby Unit ‘B’ – now the Online unit –

becomes faulted and Unit ‘A’ is clear of any faults. Operation cannot revert to the

original Online modem, Unit 'A, until it clears its faults.

(Utility: 1:1) Force

This Unit is in Standby (1:1 only)

This screen identifies the conditional state for, and allows you to execute, a forced switchover as

follows:

Message

Description

1:1 redundancy is Not Connected

This message indicates that the modem’s rear panel J2 | REDUNDANCY

connector is not connected to a supported 1:1 redundancy switch such as

the CRS-170A or CRS-180.