beautypg.com

Comtech EF Data CDM-760 User Manual

Page 264

background image

Serial-based Remote Product Management

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

8–30

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

PIIC Rx Buffer

Size

RBS =

6 bytes

Command or Query.

Sets or returns Rx Buffer Size (in ms), in the form sxxx.x where:

s = Interface Slot, where:

1 = Slot 1

2 = Slot 2

xxx.x = Rx Buffer Size, in 0.5 ms steps, from 2.0 to 75.0 ms

EXAMPLE: <0/RBS=1032.5 (selects 32.5 ms for Slot 1)

RBS=

RBS?

RBS*

RBS#

RBS?s

RBS=sxxx.x

(see Description of

Arguments)

Re Center

Buffer

RCB = s

1 byte

Command only.

Force the software to recenter the receive buffer.

s = Interface Slot, where:

1 = Slot 1

2 = Slot 2

EXAMPLE: <0/RCB=2 (re-centers the buffer on the Slot 2 interface card)

RCB=

RCB?

RCB#

RCB*

N/A

N/A