7–61

Router Errors

Item

Description

IP Header Errors

One of the following errors occurred:

The TTL (Time To Live) errors is ‘0’

The packet(s) received with Unicast MAC Address does not

match the P0 | MGMT port MAC Address.

The IP Header checksum failed

IP Dest Errors

The number of input packets discarded because the IP Address in the

IP Header's destination field was not a valid address to be received at

this modem.

No Route Errors

No route was found for the Destination IP Address.

Buffer Full Errors

The number of input + output packets for which no problems were

encountered, but which were discarded for lack of buffer space.

Management Counters

Item

Description

Management Received Packets

Total number of packets received by the modem’s Management IP

Address since last clear.

Management Transmitted Packets

Total number of packets sent by the modem’s Management IP

Address since last clear.