Front Panel Operation
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
6–35
Mask State
Front Panel
LED ‘UNIT
STATUS’ Color
Fault State
Causes
Redundancy
Switch
Mutes
Tx Carrier
Front Panel VFD
Visible Location
Mask
None
None
No
No
None: A masked event is
not logged and is not
seen in any menu.
Fault-Tx On
Red
J1 Alarm
Connector
Yes
No
Monitor: Stored-Events Log
(CONFIG: INTF) (PIICX=G703) BufSize (Rx Buffer Size)
Rx Buffer Size: 02.0 ms
()
Use the arrow keys to change the Rx Buffer Size time value. Press ENTER.
Valid settings are:
Range
Step Size
Minimum
Maximum
2 ms
75 ms
0.5 ms
(CONFIG: INTF) (PIICX=G703) Center (Rx Buffer Re-Center)
PIICX: Type:E3 ClkSource Mask
BufSize:32.0ms Center:No Fill=50% ()
The Fill Status is a read-only status of buffer depth, reported as a percentage:
•
If the Fill Status is decreasing (approaching 0%), then the Rx traffic is arriving too slowly for the
Rx Clock setting, causing a data underflow.
•
If the Fill Status is increasing (approaching 100%), then the Rx traffic is arriving too quickly for
the Rx Clock setting, causing a data overflow.
If this value indicates a data underflow or overflow, then use the arrow keys to select Yes
to re-center the Rx Buffer depth to 50%.
6.2.2.4.4.2 (CONFIG:) INTF (PIICX=OC3/STM1)
You can access this menu only when a PIIC OC3/STM1 module is installed in a PIIC
slot.
PIICX: Type:OC3/STM1 ClkSource Mask
BufSize:32.0ms Center:No Fill=50% ()