Terrestrial, Data, Connector – Comtech EF Data CDM-760 User Manual

Page 56: Group, 4 j4 | mgmt connector, rj-45f, 5 j8 | ext ref (external reference) connector, bnc

background image

Rear Panel Connections

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

3–8

3.2.2.4 J4 | MGMT Connector, RJ-45F

The RJ-45 female J4 | MGMT connector is an auto-sensing, auto-crossover port. It is

reserved for use as 10/100/1000 Ethernet-based remote management and control

(M&C).

The connector pinouts are as follows:

Pin #

Description

Direction (I/O)

1

TRP1+

I/O

2

TRP1-

I/O

3

TRP2+

I/O

4

TRP3+

I/O

5

TRP3-

I/O

6

TRP2-

I/O

7

TRP4+

I/O

8

TRP4-

I/O

3.2.2.5 J8 | EXT REF (External Reference) Connector, BNC

The J8 | EXT REF Type ‘BNC’ female input/output connector is used to supply a

master reference to the entire chassis. The internal 10 MHz reference is phase

locked to this input, if selected. The frequency references on the internal PWB’s

are locked to this input, when it is used.

This connector features an LED labeled “EXT REF OUT” that lights amber to indicate the

presence of an outgoing signal. The LED is dark when the external reference signal is incoming.

When External Reference is not used, the unit will output the internal 10 MHz reference

(stability ±06 ppm).

Ref Des Name

Connector Type

Description

Direction (I/O)

J8

EXT REF OUT

BNC

External Reference

I/O