Terrestrial, Data, Connector – Comtech EF Data CDM-760 User Manual
Page 56: Group, 4 j4 | mgmt connector, rj-45f, 5 j8 | ext ref (external reference) connector, bnc

Rear Panel Connections
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
3–8
3.2.2.4 J4 | MGMT Connector, RJ-45F
The RJ-45 female J4 | MGMT connector is an auto-sensing, auto-crossover port. It is
reserved for use as 10/100/1000 Ethernet-based remote management and control
(M&C).
The connector pinouts are as follows:
Pin #
Description
Direction (I/O)
1
TRP1+
I/O
2
TRP1-
I/O
3
TRP2+
I/O
4
TRP3+
I/O
5
TRP3-
I/O
6
TRP2-
I/O
7
TRP4+
I/O
8
TRP4-
I/O
3.2.2.5 J8 | EXT REF (External Reference) Connector, BNC
The J8 | EXT REF Type ‘BNC’ female input/output connector is used to supply a
master reference to the entire chassis. The internal 10 MHz reference is phase
locked to this input, if selected. The frequency references on the internal PWB’s
are locked to this input, when it is used.
This connector features an LED labeled “EXT REF OUT” that lights amber to indicate the
presence of an outgoing signal. The LED is dark when the external reference signal is incoming.
When External Reference is not used, the unit will output the internal 10 MHz reference
(stability ±06 ppm).
Ref Des Name
Connector Type
Description
Direction (I/O)
J8
EXT REF OUT
BNC
External Reference
I/O