Chapter 9 Running Your Library

Shutting Down, Powering Off, and Completely Removing Power

Dell PowerVault ML6000 User’s Guide

162

Shutting Down, Powering Off, and Completely Removing
Power

The

Shutdown

command shuts down the library’s operating system and

firmware. When performing a shutdown, the library finishes the current

command and lowers the robot to the floor of the library.

Before performing a shutdown, make sure the connected host

applications are not sending commands to the library.

To power off the library:

Perform the shutdown sequence and then press

the power button on the front of the 5U Library Control Module.

To completely remove power:

Perform the shutdown sequence and power

off the library. Then turn off the power switch on each power supply,

located at the rear of the library. Finally, disconnect the power supply

cables from their electrical source.
The paths to open the appropriate screens are as follows:

• From the Web client, select

Operations > System Shutdown

.

• From the operator panel, select

Operations > Shutdown

.

Restarting the Library

The

Restart

command shuts down and restarts the library’s operating

system and firmware. When performing a restart, the library finishes the

current command, then shuts down the library and restarts it. During the

restart, the library brings all tape drives and partitions online and

performs an inventory of cartridges, tape drives, and slots.
Before performing a restart, make sure the connected host applications

are not sending commands to the library.

Caution:

Always perform a shutdown before powering off the

library or completely removing power from the library.