Enable snmp v1/v2, Enable ipv6, Enable smi-s – Dell PowerVault ML6000 User Manual
Page 129: Unlabeled media detection

Chapter 5 Configuring Your Library
Configuring System Settings
Dell PowerVault ML6000 User’s Guide
129
Enable SNMP V1/V2
5
Enables Simple Network Management Protocol (SNMP) V1 and V2c
services to run on the library. This option is disabled by default.
Enable IPv6
5
Enables support for IPv6. This option is disabled by default.
The path to open the appropriate screen is as follows:
• From the operator panel, select
Setup > System Settings
.
Enable SMI-S
5
Enables the SMI-S service to run on the library. This setting is disabled by
default.
The path to open the appropriate screen is as follows:
• From the operator panel, select
Setup > System Settings
.
Unlabeled Media
Detection
5
At bootup and other times the library performs an inventory of all slots
and media. If a slot contains media with an unreadable barcode label (for
example, the label is missing, torn, or marked up), the scanner cannot
identify it, so the library normally reports the slot as empty.
With the Unlabeled Media Detection feature, you can configure the
library to detect and report which slots contain media with unreadable
barcodes. Since cartridges with unreadable barcodes will not work for
Note:
SNMP v3 is always enabled. For more information on
Configuring SNMP Settings on the Library
Note:
This setting differs from opening the SNMP port in the
Tools > Security
on page 124). In order to run SNMP, the port must
be open and the SNMP service must be enabled.
Note:
This setting differs from opening the SMI-S port in the
Tools > Security
on page 124). In order to run SMI-S, the port must
be open and the SMI-S service must be enabled.