Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 76
2–10
Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
First Clamp Close Profile Setpoints
Word
Description
CPC09
Segment 1 Velocity Setpoint [07] or [08]
if:
then the module:
you select Vel/Pos profile execution
controls clamp close speed to this setpoint after starting the First Clamp Close Profile
until clamp position reaches the larger of CPC11 or CPC61
CPC03-B14 is RESET
reads this parameter in percent velocity
CPC03-B14 is SET
reads it in in.(mm)/s
CPC10
Segment 1 Pressure Setpoint [02]
if:
then the module:
you select Press/Pos profile execution
controls clamp close pressure to this setpoint after starting the First Clamp Close Profile
until clamp position reaches the larger of CPC11 or CPC61
CPC11
End of Segment 1 Position Setpoint [14]
CPC12
Segment 2 Velocity Setpoint [07] or [08]
if:
then the module:
you select Vel/Pos profile execution
controls clamp close speed to this setpoint from the clamp position CPC11 until clamp
position reaches the larger of CPC14 or CPC61
CPC03-B14 is RESET
reads this parameter in percent velocity
CPC03-B14 is SET
reads it in in.(mm)/s
CPC13
Segment 2 Pressure Setpoint [02]
if:
then the module:
you select Press/Pos profile execution
controls clamp close pressure to this setpoint from the clamp position CPC11 until clamp
position reaches the larger of CPC14 or CPC61
CPC14
End of Segment 2 Position Setpoint [14]
CPC15
Segment 3 Velocity Setpoint [07] or [08]
if:
then the module:
you select Vel/Pos profile execution
controls clamp close speed to this setpoint from the clamp position CPC14 until clamp
position reaches the larger of CPC17 or CPC61
CPC03-B14 is RESET
reads this parameter in percent velocity
CPC03-B14 is SET
reads it in in.(mm)/s
CPC16
Segment 3 Pressure Setpoint [02]
if:
then the module:
you select Press/Pos profile execution
controls clamp close pressure to this setpoint from the clamp position CPC14 until clamp
position reaches the larger of CPC17 or CPC61
CPC17
End of Segment 3 Position Setpoint [14]
Second Clamp Close Profile Setpoints
Word
Description
CPC18
Segment 4 Velocity Setpoint [07] or [08]
if:
then the module:
you select Vel/Pos profile execution
controls clamp close speed to this setpoint after starting the Second Clamp Close Profile
until clamp position reaches the larger of CPC20 or CPC61
CPC03-B14 is RESET
reads this parameter in percent velocity
CPC03-B14 is SET
reads it in in.(mm)/s
CPC19
Segment 4 Pressure Setpoint [02]
if:
then the module:
you select Press/Pos profile execution
controls clamp close pressure to this setpoint after starting the Second Clamp Close
Profile until clamp position reaches the larger of CPC20 or CPC61
CPC20
End of Segment 4 Position Setpoint [14]