Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 261
![background image](/manuals/579944/261/background.png)
4–37
Programming Error Codes
Publication 1771-6.5.88 – July 1997
Error Code
Description
ID = 15
0736
PPC36 cannot be 00000 when PPC38 > 00000.
0739
PPC39 cannot be 00000 when PPC42 > 00000.
0740
PPC40 cannot be 00000 when PPC42 > 00000.
0743
PPC43 cannot be 00000 when PPC46 > 00000.
0744
PPC44 cannot be 00000 when PPC46 > 00000.
0747
PPC47 cannot be 00000 when PPC50 > 00000.
0748
PPC48 cannot be 00000 when PPC50 > 00000.
0815
PPC15 must be 00000 when PPC11 = 00000.
0816
PPC16 must be 00000 when PPC12 = 00000.
0819
PPC19 must be 00000 when PPC15 = 00000.
0820
PPC20 must be 00000 when PPC16 = 00000.
0823
PPC23 must be 00000 when PPC19 = 00000.
0824
PPC24 must be 00000 when PPC20 = 00000.
0827
PPC27 must be 00000 when PPC23 = 00000.
0828
PPC28 must be 00000 when PPC24 = 00000.
0831
PPC31 must be 00000 when PPC27 = 00000.
0832
PPC32 must be 00000 when PPC28 = 00000.
0835
PPC35 must be 00000 when PPC31 = 00000.
0836
PPC36 must be 00000 when PPC32 = 00000.
0839
PPC39 must be 00000 when PPC35 = 00000.
0840
PPC40 must be 00000 when PPC36 = 00000.
0843
PPC43 must be 00000 when PPC39 = 00000.
0844
PPC44 must be 00000 when PPC40 = 00000.
0847
PPC47 must be 00000 when PPC43 = 00000.
0848
PPC48 must be 00000 when PPC44 = 00000.
0961
PPC61 is too large.
if:
then:
MCC13 and MCC14
PPC61 must be within MCC13 + PPC61 + PRC05
≤
MCC14
are both non-zero
MCC13 is zero and
PPC61 must be within MCC09 + PPC61 + PRC05
≤
MCC14
is non-zero
MCC13 is non-zero and
PPC61 must be within MCC13 + PPC61 + PRC05
≤
MCC10
MCC14 is zero
MCC13 and MCC14
PPC61 must be within MCC09 + PPC61 + PRC05
≤
MCC10
are both zero
0962
PPC62 is too large.
if:
then:
MCC13 and MCC14
PPC62 must be within MCC13 + PPC61 + PPC62 + PSC05
are both non-zero
≤
MCC14
MCC13 is zero and
PPC62 must be within MCC09 + PPC61 + PPC62 + PSC05
MCC14 is non-zero
≤
MCC14
MCC13 is non-zero and
PPC62 must be within MCC13 + PPC61 + PPC62 + PSC05
MCC14 is zero
≤
MCC10
MCC13 and MCC14
PPC62 must be within MCC09 + PPC61 + PPC62 + PSC05
are both zero
≤
MCC10
1015
PPC15 is not in increasing positional order.
If non-zero, PPC15 must be greater than PPC11.
1019
PPC19 is not in increasing positional order.
If non-zero, PPC19 must be greater than PPC15.
1023
PPC23 is not in increasing positional order.
If non-zero, PPC23 must be greater than PPC19.