Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 207

3–31
Status Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
SYS
Word
Bit
Description
B08
= 0 Normal
= 1 High Screw Rotate Jog RPM
The module sets this bit when responding to command DYC01-B09 = 1 and real-time screw RPM equals or exceeds
JGC05.
B09
= 0 Normal
= 1 High Ram (Screw) Jog Pressure
The module sets this bit when responding to command DYC01-B10 = 1 or DYC01-B11 = 1 and real-time ram (screw)
pressure equals or exceeds JGC06.
B10
= 0 Normal
= 1 High Clamp Jog Pressure
The module sets this bit when responding to command DYC01-B12 = 1 or DYC01-B13 = 1 and real-time clamp pres-
sure equals or exceeds JGC07.
B11
= 0 Normal
= 1 High Ejector Jog Pressure
The module sets this bit when responding to command DYC01-B14 = 1 or DYC01-B15 = 1 and real-time ejector pres-
sure equals or exceeds JGC08.
B12
= 0 Normal
= 1 First Clamp Close Profile High Clamp Pressure
The module sets this bit when real-time clamp pressure equals or exceeds FCC57.
B13
= 0 Normal
= 1 Second Clamp Close Profile High Clamp Pressure
The module sets this bit when real-time clamp pressure equals or exceeds SCC57.
B14
= 0 Normal
= 1 Third Clamp Close Profile High Clamp Pressure
The module sets this bit when real-time clamp pressure equals or exceeds TCC57.
B15
= 0 Normal
= 1 Clamp Low Press Close Profile High Clamp Pressure
The module sets this bit when real-time clamp pressure equals or exceeds LPC57.
SYS06
High Pressure Alarm Status (Real Time)
The module sets alarm bits on a real-time basis. These bits are not latched.
You can inhibit each bit by setting its associated alarm setpoint to zero.
B00
= 0 Normal
= 1 Injection Profile High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds INC57.
B01
= 0 Normal
= 1 Injection Profile High Cavity Pressure
The module sets this bit when real-time cavity pressure equals or exceeds INC58.
B02
= 0 Normal
= 1 Pack Profile High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds PKC57.
B03
= 0 Normal
= 1 Pack Profile High Cavity Pressure
The module sets this bit when real-time cavity pressure equals or exceeds PKC58.
B04
= 0 Normal
= 1 Hold Profile High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds HDC57.
B05
= 0 Normal
= 1 Hold Profile High Cavity Pressure
The module sets this bit when real-time cavity pressure equals or exceeds HDC58.
B06
= 0 Normal
= 1 Pre-decompress Movement High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds PRC57.
B07
= 0 Normal
= 1 Plastication Profile High Ram (Screw) Pressure
The module sets this bit when real-time ram (screw) pressure equals or exceeds PLC57.