Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 229
4–5
Programming Error Codes
Publication 1771-6.5.88 – July 1997
Error Code
Description
ID = 1
0432
MCC32 is out of range. Valid range is MCC31 < MCC32
≤
09999
0435
MCC35 is out of range.
If non-zero, MCC35 must be within MCC31 < MCC35
≤
MCC32
0437
MCC37 is out of range. Valid range is 00000
≤
MCC37 < MCC38
0438
MCC38 is out of range. Valid range is MCC37 < MCC38
≤
09999
0441
Your non-zero entry for MCC41 is out of range.
If MCC42 is non-zero, MCC41 must be within MCC37
≤
MCC41 < MCC42
If MCC42 is zero, MCC41 must be within MCC37
≤
MCC41 < MCC38
0442
Your non-zero entry for MCC42 is out of range.
If MCC41 is non-zero, MCC42 must be within MCC41 < MCC42
≤
MCC38
If MCC41 is zero, MCC42 must be within MCC37 < MCC42
≤
MCC38
0445
MCC45 is out of range. Valid range is 00000
≤
MCC45 < MCC46
0446
MCC46 is out of range. Valid range is MCC45 < MCC46
≤
09999
0449
MCC49 is out of range.
If non-zero, MCC49 must be within MCC45 < MCC49
≤
MCC46
0451
MCC51 is out of range. Valid range is 00000
≤
MCC51 < MCC52
0452
MCC52 is out of range. Valid range is MCC51 < MCC52
≤
09999
0455
MCC55 is out of range.
If non-zero, MCC55 must be within MCC51 < MCC55
≤
MCC52
0457
MCC57 is out of range. Valid range is 00000
≤
MCC57 < MCC58
0458
MCC58 is out of range. Valid range is MCC57 < MCC58
≤
20000
0461
MCC61 is out of range.
If non-zero, MCC61 must be within MCC57 < MCC61
≤
MCC58
0502
You configured the module for 4x4 I/O by MCC02-B03 = 1.
Therefore, MCC02-B04 = 1 and MCC02-B05 = 1 is illegal.
0503
You configured the module for 4x4 I/O by MCC02-B03 = 1.
Therefore, your bit pattern in the upper byte of MCC03 must be 11111111 to indicate that
inputs #5 through #8 are “unconnected”.
0504
You configured the module for 4x4 I/O by MCC02-B03 = 1.
Therefore, your bit pattern in the upper byte of MCC04 must be 11111111 to indicate that
outputs #5 through #8 are “unconnected”.
0507
Your settings for MCC02-B03, B04, and B05 indicate that module input #1 is reserved for a
ram (screw) position transducer. Therefore MCC03-B00 and B01 cannot both = 1.
0511
Your settings for MCC02-B03, B04, and B05 indicate that module input #3 is reserved for a
clamp position transducer. Therefore MCC03-B00 and B01 cannot both = 1.
0602
You configured the module for 8x8 I/O by MCC02-B03 = 0.
This configuration is not supported by your series/revision of firmware.
0915
MCC15 is too large.
if:
then:
MCC13 and MCC14
MCC15 must be within MCC13 + MCC15 < MCC14 – MCC15
are both non-zero
MCC13 is zero and
MCC15 must be within MCC09 + MCC15 < MCC14 – MCC15
MCC14 is non-zero
MCC13 is non-zero
MCC15 must be within MCC13 + MCC15 < MCC10 – MCC15
and MCC14 is zero
0929
MCC29 is too large.
if:
then:
MCC27 and MCC28
MCC29 must be within MCC27 + MCC29 < MCC28 – MCC29
are both non-zero
MCC27 is zero and
MCC29 must be within MCC23 + MCC29 < MCC28 – MCC29
MCC28 is non-zero
MCC27 is non-zero
MCC29 must be within MCC27 + MCC29 < MCC24 – MCC29
and MCC28 is zero