Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
CPC
Word
Bit
Description
B11
Mold Protection Zone Overrun Selection
= 0 Start Clamp Low Pressure Close Profile on Mold Protection Zone Overrun
= 1 Stop and Zero Outputs on Mold Protection Zone Overrun
During any of the first three Clamp Close Profiles,
if B11 is:
then the module:
clamp position reaches a value immediately terminates the ongoing Clamp Close Profile and checks this bit
less than or equal to CPC61
RESET
immediately begins the Clamp Low Pressure Close Profile
SET
sets its outputs to zero
B12-B13
Open
B14
Velocity Units Selection
= 0 Velocity Parameters in Percent Velocity
= 1 Velocity Parameters in in.(mm)/s
if B14 is: then the module:
RESET
returns all segment velocity actuals (and assumes all velocity setpoints) in units of percent velocity where
FCC46, SCC46, and TCC46 represent 100% velocity
SET
returns all velocity actuals (and assumes all velocity setpoints) in units of in.(mm)/s
B15
Open
CPC04
Configuration Selections
Open/Closed Loop Selection
B00
= 0 Vel/Pos First Clamp Close Profiles Closed Loop
= 1 Vel/Pos First Clamp Close Profiles Open Loop
B01
= 0 Press/Pos First Clamp Close Profiles Closed Loop
= 1 Press/Pos First Clamp Close Profiles Open Loop
B02
= 0 Vel/Pos Second Clamp Close Profiles Closed Loop
= 1 Vel/Pos Second Clamp Close Profiles Open Loop
B03
= 0 Press/Pos Second Clamp Close Profiles Closed Loop
= 1 Press/Pos Second Clamp Close Profiles Open Loop
B04
= 0 Vel/Pos Third Clamp Close Profiles Closed Loop
= 1 Vel/Pos Third Clamp Close Profiles Open Loop
B05
= 0 Press/Pos Third Clamp Close Profiles Closed Loop
= 1 Press/Pos Third Clamp Close Profiles Open Loop
B06
Open
B07
= 0 Clamp Low Pressure Close Profiles Closed Loop
= 1 Clamp Low Pressure Close Profiles Open Loop
ERC Enabled/Disabled Selection
B08
= 0 Vel/Pos First Clamp Close Profiles ERC On
= 1 Vel/Pos First Clamp Close Profiles ERC Off
B09
= 0 Press/Pos First Clamp Close Profiles ERC On
= 1 Press/Pos First Clamp Close Profiles ERC Off
B10
= 0 Vel/Pos Second Clamp Close Profiles ERC On
= 1 Vel/Pos Second Clamp Close Profiles ERC Off
B11
= 0 Press/Pos Second Clamp Close Profiles ERC On
= 1 Press/Pos Second Clamp Close Profiles ERC Off
B12
= 0 Vel/Pos Third Clamp Close Profiles ERC On
= 1 Vel/Pos Third Clamp Close Profiles ERC Off
B13
= 0 Press/Pos Third Clamp Close Profiles ERC ON
= 1 Press/Pos Third Clamp Close Profiles ERC Off
B14
Open
B15
= 0 Clamp Low Pressure Close Profiles ERC On
= 1 Clamp Low Pressure Close Profiles ERC Off
CPC05 - 08
Open