2–8
Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Word
Description
CLC41
Ejector Full Retract Segment 3
CLC42
Reserved
CLC43 - 64
Open
Bit-mapped Control Words
Word
Bit
Description
CPC01
Block ID = 00000111 (low byte). High byte reserved for the module. Do not use.
CPC02
Open
CPC03
Configuration Selections
Profile Algorithm Selections
B00
= 0 Vel/Pos selected for First Clamp Close Profile
= 1 Press/Pos selected for First Clamp Close Profile
B01
Open
B02
= 0 Vel/Pos selected for Second Clamp Close Profile
= 1 Press/Pos selected for Second Clamp Close Profile
B03
Open
B04
= 0 Vel/Pos selected for Third Clamp Close Profile
= 1 Press/Pos selected for Third Clamp Close Profile
B05-B07
Open
B08
First/Second Clamp Close Logical Bridge Selection
= 0 Start Second Clamp Close Profile at End of First Clamp Close Profile
= 1 Stop and Set-output at End of First Clamp Close Profile
The module checks this pause bit at end of the First Clamp Close Profile to determine what further action to take:
if B08 is:
then the module:
SET
sets its outputs to FCC33 - FCC40
RESET and CPC20 > 00000
immediately begins the Second Clamp Close Profile
RESET and CPC20 = 00000
reacts as if it had just completed the Second Clamp Close Profile, and
continues operation based on the state of CPC03-B09
B09
Second/Third Clamp Close Logical Bridge Selection
= 0 Start Third Clamp Close Profile at End of Second Clamp Close Profile
= 1 Stop and Set-output at End of Second Clamp Close Profile
The module checks this pause bit at end of the Second Clamp Close Profile to determine what further action to take:
if B09 is:
then the module:
SET
sets its outputs to SCC33 - SCC40
RESET and CPC29 > 00000
immediately begins the Second Clamp Close Profile
RESET and CPC29 = 00000
reacts as if it had just completed the Second Clamp Close Profile, and
continues operation based on the state of CPC03-B10
B10
Third Clamp Close/Clamp Low Press Close (LPC) Logical Bridge Selection
= 0 Start Clamp LPC Profile at End of Third Clamp Close Profile
= 1 Stop and Set-output at End of Third Clamp Close Profile
The module checks this pause bit at end of the Third Clamp Close Profile to determine what further action to take:
if B10 is:
then the module:
SET
sets its outputs to TCC33 - TCC40
RESET
immediately begins the Clamp Low Pressure Close Profile
CPC – Clamp Close