Plc plastication configuration command block (plc), Plastication configuration command block (plc) – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 151
2–85
Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
PLC
Bit-mapped Control Words
Word
Bit
Description
PLC01
Block ID = 00001110 (Low byte). High byte reserved for the module. Do not use.
PLC02
Configuration Selections
B00-B02
Selected RPM Control Valve
The module uses its algorithm to drive the following output during any RPM/Pos or RPM/Time Plastication Profile.
B02 B01 B00
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8
PLC02
B03
RPM Algorithm Selection
= 0 Dependent Gains (ISA)
= 1 Independent Gains (A-B)
B04-B06
Selected Pressure Control Valve
The module uses its algorithm to drive the following output during any RPM/Pos or RPM/Time Plastication Profile.
B06 B05 B04
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8
B07
Pressure Algorithm Selection
= 0 Dependent Gains (ISA)
= 1 Independent Gains (A-B)
B08-B15
Open
PLC03 - 04
Open
Expert Response Compensation (ERC) Percentage
Word
Description
PLC05
Minimum RPM Control ERC Percentage [31]
PLC06
Minimum Pressure Control ERC Percentage [31] Although error coding allows range of 00000 to 09999, the module limits it to a
minimum of 01000.
PLC07
Open
Watchdog Timer
Word
Description
PLC08
Profile Watchdog Timer Preset [21] When the module starts Plastication Profile, it:
S
starts an internal Profile Watchdog timer
S
stops this timer and reset its accumulated value to zero (after reporting total execution time in PPS57) when it completes the profile
S
sets master status bit SYS04-B08 when the accumulated value of this timer equals or exceeds this entry
A zero entry inhibits SYS04-B08.
Plastication Configuration
Command Block (PLC)