Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 152

2–86
Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Unselected Valve Set-output Values
When the module starts the Plastication Profile, it:
•
sets its unselected outputs to the values listed below
•
ignores the unselected value of the selected output
•
uses ramp rates PLC17 - PLC32 to ramp unselected outputs
Word
Description
PLC09
Output #1 Set-output Value during Profile [19]
PLC10
Output #2 Set-output Value during Profile [19]
PLC11
Output #3 Set-output Value during Profile [19]
PLC12
Output #4 Set-output Value during Profile [19]
PLC13
Output #5 Set-output Value during Profile [19]
PLC14
Output #6 Set-output Value during Profile [19]
PLC15
Output #7 Set-output Value during Profile [19]
PLC16
Output #8 Set-output Value during Profile [19]
Output Ramp Rates
The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the Plastication Profile. The module
interprets a ramp rate of zero as a step function ramp (ramp disable).
Word
Description
PLC17
Output #1 Acceleration Ramp Rate during Profile [20]
PLC18
Output #2 Acceleration Ramp Rate during Profile [20]
PLC19
Output #3 Acceleration Ramp Rate during Profile [20]
PLC20
Output #4 Acceleration Ramp Rate during Profile [20]
PLC21
Output #5 Acceleration Ramp Rate during Profile [20]
PLC22
Output #6 Acceleration Ramp Rate during Profile [20]
PLC23
Output #7 Acceleration Ramp Rate during Profile [20]
PLC24
Output #8 Acceleration Ramp Rate during Profile [20]
PLC25
Output #1 Deceleration Ramp Rate during Profile [20]
PLC26
Output #2 Deceleration Ramp Rate during Profile [20]
PLC27
Output #3 Deceleration Ramp Rate during Profile [20]
PLC28
Output #4 Deceleration Ramp Rate during Profile [20]
PLC29
Output #5 Deceleration Ramp Rate during Profile [20]
PLC30
Output #6 Deceleration Ramp Rate during Profile [20]
PLC31
Output #7 Deceleration Ramp Rate during Profile [20]
PLC32
Output #8 Deceleration Ramp Rate during Profile [20]
End of Profile Set-output Values
When the module completes the Plastication Profile and PPC03-B08
is set, it:
•
sets its outputs to the following values
•
sets status bit SYS22-B08
•
uses ramp rates PLC17 - 32 when changing outputs to these values